PSU8600 power supply system
Modular system, buffer (BUF8600)
■
Overview
The BUF8600 buffer modules with maintenance free energy
storage units are part of the SITOP PSU8600 modular system
and are designed to bridge short-term power failures. They
automatically take over the DC power supply in case of a line
voltage failure. You can connect up to two BUF8600 buffer
modules to the PSU8600 basic unit. Connection takes place on
top of the modules without any wiring by means of the System
Clip Link, a connecting plug for system data and power supply.
Main product highlights
•
Reliable bridging of short-term power failures up to maximum
20 s (at 24 V DC and full load)
•
Buffer module with maintenance free electrolytic capacitors
for bridging short-term power failures (brownouts) between
100 ms and max. 600 ms (at 24 V DC/40 A)
•
Buffer module with maintenance free double-layer capacitors
for bridging longer power failures between 4 s and max. 20 s
(at 24 V DC/40 A)
•
The two buffer modules can be combined as required.
•
Easy connection without wiring overhead
■
Technical specifications
Article number
6EP4297-8HB00-0XY0
6EP4297-8HB10-0XY0
6EP4293-8HB00-0XY0
6EP4295-8HB00-0XY0
product brand name
SITOP BUF8600
SITOP BUF8600
SITOP BUF8600
SITOP BUF8600
Type of current supply
100 ms/40 A
300 ms/40 A
4 s/40 A
10 s/40 A
Mains buffering
Type of energy storage
electrolytic capacitors
electrolytic capacitors
Double-layer capacitors
Double-layer capacitors
Buffering time for rated value of the
output current in the event of power
failure
100 ms
300 ms
4 s
10 s
Output
Output current
• Rated value
40 A
40 A
40 A
40 A
Signaling
Display version
3-color LED for operating
state module
3-color LED for operating
state module
3-color LED for operating
state module
3-color LED for operating
state module
• for normal operation
LED green for
"buffer standby exist"
LED green for
"buffer standby exist"
LED green for
"buffer standby exist"
LED green for
"buffer standby exist"
• in buffering mode
LED yellow for
"buffered mode"
LED yellow for
"buffered mode"
LED yellow for
"buffered mode"
LED yellow for
"buffered mode"
Interface
Specification/Interface
Ethernet/PROFINET via
power supply unit PSU8600
Ethernet/PROFINET via
power supply unit PSU8600
Ethernet/PROFINET via
power supply unit PSU8600
Ethernet/PROFINET via
power supply unit PSU8600
Safety
Protection class
Class III
Class III
Class III
Class III
CE marking
Yes
Yes
Yes
Yes
UL/cUL (CSA) approval
cULus-Listed (UL 508,
CSA C22.2 No. 107.1),
File E197259; cCSAus
(CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-Listed (UL 508,
CSA C22.2 No. 107.1),
File E197259; cCSAus
(CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-Listed (UL 508,
CSA C22.2 No. 107.1),
File E197259; cCSAus
(CSA C22.2 No. 60950-1,
UL 60950-1)
cULus-Listed (UL 508,
CSA C22.2 No. 107.1),
File E197259; cCSAus
(CSA C22.2 No. 60950-1,
UL 60950-1)
Explosion protection
IECEx nA IIC T5 Gc; ATEX
(EX) II 3G Ex nA IIC T5 Gc
IECEx nA IIC T5 Gc; ATEX
(EX) II 3G Ex nA IIC T5 Gc
IECEx nA IIC T5 Gc; ATEX
(EX) II 3G Ex nA IIC T5 Gc
IECEx nA IIC T5 Gc; ATEX
(EX) II 3G Ex nA IIC T5 Gc
CB approval
Yes
Yes
Yes
Yes
Shipbuilding approval
GL (ABS in process)
GL (ABS in process)
GL (ABS in process)
GL (ABS in process)
Protection class (EN 60529)
IP20
IP20
IP20
IP20
EMC
Emitted interference
EN 55022 Class B
EN 55022 Class B
EN 55022 Class B
EN 55022 Class B
Noise immunity
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2
© Siemens AG 2016