SIEMENS
11/20
Siemens KT 10.1 · 2016
11
■
Technical specifications
(continued)
SITOP DC UPS uninterruptible power supplies
DC UPS with battery modules
SITOP UPS1100 battery modules
Ambient temperature
during storage Note
Along with the
storage and
operating
temperature, other
factors such as the
duration of the
storage period and
the charge status
during storage have
a decisive influence
on the possible useful
life. Batteries should
therefore be stored
as briefly as possible,
always fully charged,
and within the
temperature range
0 to +20 °C.
Along with the
storage and
operating
temperature, other
factors such as the
duration of the
storage period and
the charge status
during storage have
a decisive influence
on the possible useful
life. Batteries should
therefore be stored
as briefly as possible,
always fully charged,
and within the
temperature range
0 to +20 °C.
Along with the
storage and
operating
temperature, other
factors such as the
duration of the
storage period and
the charge status
during storage have
a decisive influence
on the possible useful
life. Batteries should
therefore be stored
as briefly as possible,
always fully charged,
and within the
temperature range
0 to +20 °C.
Along with the
storage and
operating
temperature, other
factors such as the
duration of the
storage period and
the charge status
during storage have
a decisive influence
on the possible useful
life. Batteries should
therefore be stored
as briefly as possible,
always fully charged,
and within the
temperature range
0 to +20 °C.
Along with the
storage and
operating
temperature, other
factors such as the
duration of the
storage period and
the charge status
during storage have
a decisive influence
on the possible useful
life. Batteries should
therefore be stored
as briefly as possible,
always fully charged,
and within the
temperature range
0 to +20 °C.
Along with the
storage and
operating
temperature, other
factors such as the
duration of the
storage period and
the charge status
during storage have
a decisive influence
on the possible useful
life. Batteries should
therefore be stored
as briefly as possible,
always fully charged,
and within the
temperature range
0 to +20 °C.
Mechanics
Connection
technology
screw-type terminals
screw-type terminals
screw-type terminals
screw-type terminals
screw-type terminals
screw-type terminals
Connection for power
supply unit
1 screw terminal
each for 0.2 ... 6 mm²
for + BATT and -
BATT
1 screw terminal
each for 0.2 ... 6 mm²
for + BATT and -
BATT
1 screw terminal
each for 0.2 ... 6 mm²
for + BATT and -
BATT
1 screw terminal
each for 0.5 ... 16
mm² for + BATT and -
BATT
1 screw terminal
each for 0.5 ... 16
mm² for + BATT and -
BATT
1 screw terminal
each for 0.5 ... 16
mm² for + BATT and -
BATT
Type of electrical
connection for control
circuit and status
message
1 screw terminal
each for
0.14 ... 4 mm²
1 screw terminal
each for
0.14 ... 4 mm²
1 screw terminal
each for
0.14 ... 4 mm²
1 screw terminal
each for
0.14 ... 4 mm²
1 screw terminal
each for
0.14 ... 4 mm²
1 screw terminal
each for
0.14 ... 4 mm²
Product component
belonging to
Accessories pack
with solid-state
circuitry fuse 15 A
Accessories pack
with solid-state
circuitry fuse 25 A
Accessories pack
with solid-state
circuitry fuse 25 A
Accessories pack
with solid-state
circuitry fuse 15 A
Accessories pack
with solid-state
circuitry fuse 25 A
Accessories pack
with solid-state
circuitry fuse 25 A
Width of the
enclosure
89 mm
265 mm
190 mm
189 mm
186 mm
253 mm
Height of the
enclosure
130.3 mm
115 mm
169.3 mm
186 mm
186 mm
186 mm
Depth of the
enclosure
106.7 mm
76 mm
78.7 mm
112.7 mm
110.3 mm
110.3 mm
Installation width
89 mm
265 mm
190 mm
189 mm
186 mm
253 mm
Installation height
145.3 mm
130 mm
184.3 mm
201 mm
201 mm
201 mm
Weight, approx.
1.9 kg
3.7 kg
3.8 kg
3.4 kg
6.1 kg
9.8 kg
Installation
snaps onto DIN rail
EN 60715 35x7.5/15
or keyhole mounting
for hooking in to M4
screws
snaps onto DIN rail
EN 60715 35x7.5/15
or keyhole mounting
for hooking in to M4
screws
snaps onto DIN rail
EN 60715 35x15 or
keyhole mounting for
hooking in to M4
screws
snaps onto DIN rail
EN 60715 35x7.5/15
or keyhole mounting
for hooking in to M4
screws
can be screwed onto
flat surface (keyhole
mounting for hooking
in to M4 screws)
can be screwed onto
flat surface (keyhole
mounting for hooking
in to M4 screws)
Number of cells
12
12
12
16
12
12
Equipment marking
acc. to
DIN EN 81346-2
G
G
G
G
G
G
Other information
Specifications at
rated input voltage
and ambient
temperature +25 °C
(unless otherwise
specified)
Specifications at
rated input voltage
and ambient
temperature +25 °C
(unless otherwise
specified)
Specifications at
rated input voltage
and ambient
temperature +25 °C
(unless otherwise
specified)
Specifications at
rated input voltage
and ambient
temperature +25 °C
(unless otherwise
specified)
Specifications at
rated input voltage
and ambient
temperature +25 °C
(unless otherwise
specified)
Specifications at
rated input voltage
and ambient
temperature +25 °C
(unless otherwise
specified)
Article number
6EP4131-0GB00-
0AY0
6EP4132-0GB00-
0AY0
6EP4133-0GB00-
0AY0
6EP4133-0JB00-
0AY0
6EP4134-0GB00-
0AY0
6EP4135-0GB00-
0AY0
Product
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100
Product type
Lead battery
Pure-lead battery
Lead battery
LiFePo battery
Lead battery
Lead battery
Battery capacity
1.2 Ah
2.5 Ah
3.2 Ah
5 Ah
7 Ah
12 Ah
© Siemens AG 2016