SIEMENS
11/11
Siemens KT 10.1 · 2016
11
SITOP DC UPS uninterruptible power supplies
DC UPS with battery modules
SITOP UPS1600 DC UPS modules
■
Application
The battery modules that can be connected in parallel bridge
power failures for a few hours. This supports the continued
operation of processes or parts of them. The function "Starting
from the battery" means that the UPS1600 can also be used in
stand-alone mode without connection to the supply.
Depending on the communication requirements between the
DC UPS and the automation components to be protected
against power failure, the version of UPS1600 can be selected
accordingly.
Buffering of simple automation applications
In simple applications with mini PLCs (e.g. obstruction lights,
stand-alone hydro-electric plants), 24 V buffering is performed
by the UPS1600 without a communications interface. The status
messages are transferred to the PLC via the digital outputs
(isolated).
Buffering of applications with automation computer
The UPS1600 with a USB interface is used to buffer automation
solutions that are controlled by an industrial PC. All operating
and configuring data is communicated over the PC interface.
Communication over Ethernet/PROFINET offers the most
comprehensive possibilities for diagnostics and system
integration. The UPS1600 can be directly integrated into the
LAN infrastructure over its two ports.
Buffering of applications with networked
(Industrial Ethernet) automation computers
The UPS1600 with Industrial Ethernet interface protects complex
PC-based applications from power failure. Configuration and
monitoring is performed using the PC software SITOP UPS
Manager. It also supports defined shutdown of several PCs in
accordance with the master-slave principle.
Buffering of applications with networked (PROFINET)
automation components
For buffering sensitive plant components (e.g. a pumping station
with telecontrol) or complete controller solutions (e.g. machine
tools) that are integrated into a networked automation solution,
the UPS1600 with PROFINET is the perfect choice. Total integra-
tion in TIA offers unique advantages for engineering and opera-
tion (e.g. diagnostics or visualization). For example, in buffer
mode, several controllers can be brought to a defined inde-
pendently of each other.
Controlling
Uninterruptible 24 V power supply
24 V DC
Power
supply
SITOP
PM1207
G_KT01_XX_00802
SITOP
UPS1600
SITOP
UPS1100
Energy Storage Link
LOGO!
SIMATIC S7-1200
5
Controlling, configurating, monitoring
Uninterruptible 24 V power supply
Industrial PC
24 V DC
Power
supply
SITOP
G_KT01_XX_00803
SITOP
UPS1600
SITOP
UPS1100
Energy Storage Link
USB
Controlling, configurating, monitoring
Uninterruptible 24 V power supply
Control
Industrial PC
Industrial PC
24 V DC
Power
supply
SITOP
Industrial Ethernet
G_KT01_XX_00796
SITOP
UPS1600
SITOP
UPS1100
PC
Energy Storage Link
Uninterruptible 24 V power supply
Human Machine Interface
Control
Power
supply
SITOP
24 V DC
PROFINET
SITOP
UPS1600
SITOP
UPS1100
G_KT01_XX_00797
Engineering
SIMATIC S7-
300/400/
1200/1500,
STEP 7
Panel PC/ PC
SIMATIC HMI,
WinCC
PC WinCC,
SCADA
system
PG/ PC, TIA Portal,
Step 7
Energy Storage Link
© Siemens AG 2016