SITOP DC UPS uninterruptible power supplies
DC UPS with battery modules
SITOP UPS1600 DC UPS modules
■
Overview
By combining one DC UPS module SITOP UPS1600 with at least
one UPS1100 battery module and a SITOP power supply unit,
longer power failures can be bridged without any interruption.
The intelligent battery management automatically detects the
UPS1100 energy storage unit, ensures optimized temperature-
specific charging and continuous monitoring. The compact
DC UPS modules have overload capability, for example, to
supply the inrush current of industrial PCs. In stand-alone mode,
they support starting from the battery.
The DC UPS communicates openly over a USB or Ethernet/
PROFINET port. It is easily integrated into the PC or PLC environ-
ment over the two Ethernet/PROFINET ports. Total integration in
TIA provides user-friendly engineering in the TIA Portal and is
supported with ready-to-use function blocks for S7 user pro-
grams and WinCC faceplates for fast visualization.
SITOP UPS Manager supports easy monitoring and configura-
tion in PC systems, e.g. shutdown of several PCs in accordance
with the master-slave principle. The integrated web server
supports remote monitoring of the DC UPS.
■
Benefits
•
24 V buffering for a few hours for the purpose of continuing
processes
•
Open communication over USB or two Ethernet/PROFINET
ports
•
High-performance DC UPS modules in space-saving,
slim design
•
High overload capability for mains and buffering operation
•
Starting from the battery module supports stand-alone mode,
e.g. for starting generators
•
Easy configuration thanks to automatic detection of battery
modules
•
High reliability and availability due to monitoring of the opera-
tional readiness, battery feeder, aging and charging status
•
Battery protecting charging due to temperature-specific
charging characteristic
•
Defined shutdown of several PCs or controllers on one UPS
(versions with Ethernet/PROFINET)
•
Remote monitoring via integrated web server
(versions with Ethernet/PROFINET)
•
Time-saving engineering in PC-based systems via SITOP UPS
Manager (versions with USB or Ethernet/PROFINET)
•
SITOP UPS Manager with OPC UA server facilitates flexible,
multi-vendor communication with other systems
•
Full integration in TIA saves time and costs during the
planning stage and in operation (versions with Ethernet/
PROFINET)
•
User-friendly engineering in the TIA Portal
•
SIMATIC S7 function blocks for easy integration in STEP 7 user
programs
•
Fast integration in operator control and monitoring with WinCC
faceplates
•
Direct integration in SIMATIC PCS 7 via SITOP library