Main spindle motors
SIMOTICS M synchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> Forced ventilation/Water cooling
6
■
Options
Order
code
Description of option
When ordering a motor with options,
-Z
must be added to the article number.
The order code must also be stated for each required option.
Order codes must not be repeated in plain text in the order.
For use with
SIMOTICS M motors
1PH813
1PH816
1PH818
1PH822
A12
Additional PTC thermistor chain for alarm and tripping
(Only
possible for versions with terminal box.)
✔
✔
A25
Additional KTY84 temperature sensor as reserve connected to signal terminal strip
(Only
possible for versions with terminal box.)
✔
Standard
B02
Test certificate (for ordered motor)
✔
Standard
G14
Fan unit with air filter (only
possible if 11th data position is 1)
✔
✔
K08
Encoder connector or DRIVE-CLiQ mounted opposite
–
✔
K09
Terminal box or power connector NDE on the right
✔
–
(For terminal box type, see selection guides or CAD CREATOR)
1)
Terminal box NDE on the right
, cable entry DE/signal connection at top
(only
possible if 15th data position is A)
–
✔
K10
Terminal box or power connector NDE on the left
✔
–
(For terminal box type, see selection guides or CAD CREATOR)
1)
Terminal box NDE on the left
, cable entry DE/signal connection at top
(only
possible if 15th data position is A)
–
✔
K18
Radial shaft sealing ring DE
2)
(Not
possible if 14th data position is F)
✔
✔
K40
Regreasing system, DE and NDE
–
✔
K45
Anti-condensation heating 230 V AC
–
✔
K80
Axial pipe connection NDE (only
possible with forced ventilation)
✔
✔
K83
Rotation of the terminal box
by + 90°
(
only
possible in combination with options K09 or K10)
–
✔
K84
Rotation of the terminal box
by – 90°
(
only
possible in combination with options K09 or K10)
–
✔
K85
Rotation of the terminal box
by + 180°
(
only
possible in combination with options K09 or K10)
–
✔
K90
Version with flange size A400
–
✔
(only
possible if 12th data position is 2, 3 or 5)
For 1PH818 only
L00
Replace terminal box (standard) with the next larger terminal box
(Note dimension implications, see CAD CREATOR.)
–
✔
P00
Undrilled cable entry plate
–
✔
P01
Cable entry plate 3
×
M63
×
1.5
(Only
for terminal box type 1XB7700-P02)
–
✔
L03
Increased vibration stress
–
✔
L12
Condensation drain hole
–
✔
4)
L27
NDE bearing in insulated version
–
✔
For 1PH818 only
Standard for
1PH822
L74
Fan version with IP65 degree of protection
3)
✔
–
L75
Special fan version for 400 V 3 AC with IP65 degree of protection
3)
–
✔
M03
Version for potentially explosive atmospheres Zone 2
5)
✔
–
M39
Version for potentially explosive atmospheres Zone 22
5)
✔
–
Q12
M5 sealing air connection
✔
–
Q31
Metal rating plate instead of adhesive label
✔
✔
✔
Option available
–
Option not
available
1)
A different terminal box type mounted on the side is used in conjunction with options K09 or K10. Instead of gk833, gk843 is used.
Only possible with type of construction IM B3 or IM B35.
2)
Only appropriate if oil spray or oil vapor is occasionally deposited on the sealing ring.
3)
Regardless of the degree of protection, at high levels of atmospheric pollution, the fan must be cleaned.
4)
Standard for water-cooled motors.
5)
Only with direction of air flow NDE
DE (11th digit in MLFB = 1).