SIEMENS
6/132
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M synchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> SH 180 – Forced ventilation/Water cooling
6
■
Selection and ordering data
Rated
speed
Speed,
max.
1)
Operating
speed,
max.
2)
Rated
power
S1
duty
Rated torque
S1
duty
Static torque
SIMOTICS M-1PH8
synchronous motors
with
holding
brake
without
holding
brake
n
rated
n
max, Br
n
max1
2)
n
max, Inv
P
rated
M
rated
M
0
rpm
rpm
rpm
rpm
kW (HP)
Nm (lb
f
-ft)
Nm (lb
f
-ft)
Article No.
Shaft height 180 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
800
3500
3800
1450
38.0 (50.96)
454 (335)
480 (354)
1PH8184
-
■
■
C
■
■
-
■
■
■
1
1150
3500
3800
1950
53.0 (71.07)
440 (325)
480 (354)
1PH8184
-
■
■
D
■
■
-
■
■
■
1
1750
3500
3800
2700
82.0 (109.96)
447 (330)
480 (354)
1PH8184
-
■
■
F
■
■
-
■
■
■
1
800
3500
3800
1450
50.0 (67.05)
597 (440)
640 (472)
1PH8186
-
■
■
C
■
■
-
■
■
■
1
1150
3500
3800
2050
71.0 (95.21)
590 (435)
640 (472)
1PH8186
-
■
■
D
■
■
-
■
■
■
1
1750
3500
3800
2950
109 (146.17)
595 (439)
640 (472)
1PH8186
-
■
■
F
■
■
-
■
■
■
1
Shaft height 180 – Water cooling – Line voltage 400 V 3 AC, operation on Active Line Module
800
3500
3800
1450
48.0 (64.4)
573 (423)
590 (435)
1PH8184
-
■
■
C
2
■
-
■
■
■
1
1150
3500
3800
1950
70.0 (93.87)
581 (429)
600 (443)
1PH8184
-
■
■
D
2
■
-
■
■
■
1
1750
3500
3800
2700
103 (138.12)
562 (415)
600 (443)
1PH8184
-
■
■
F
2
■
-
■
■
■
1
2800
3500
3800
3800
140 (187.74)
461 (340)
530 (391)
1PH8184
-
■
■
L
2
■
-
■
■
■
1
800
3500
3800
1450
66.0 (88.51)
788 (581)
800 (590)
1PH8186
-
■
■
C
2
■
-
■
■
■
1
1150
3500
3800
2050
92.0 (123.37)
764 (564)
800 (590)
1PH8186
-
■
■
D
2
■
-
■
■
■
1
1750
3500
3800
2950
138 (185.06)
753 (555)
800 (590)
1PH8186
-
■
■
F
2
■
-
■
■
■
1
2800
3500
3800
3800
178 (238.7)
586 (432)
720 (531)
1PH8186
-
■
■
L
2
■
-
■
■
■
1
For versions, see
Article No. supplement
and options.
1)
Maximum speed that must not be exceeded.
2)
Maximum permissible operating speed based on the voltage induced in the motor and the voltage stability of the Motor Module
(without protective circuit).
© Siemens AG 2016