SIEMENS
6/130
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M synchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> SH 160 – Forced ventilation/Water cooling
6
■
Selection and ordering data
Rated
speed
Speed,
max.
1)
Operating
speed,
max.
2)
Rated
power
S1
duty
Rated torque
S1
duty
Static torque
SIMOTICS M-1PH8
synchronous motors
n
rated
n
max
n
max, Inv
P
rated
M
rated
M
0
rpm
rpm
rpm
kW (HP)
Nm (lb
f
-ft)
Nm (lb
f
-ft)
Article No.
Shaft height 160 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
1750
4000
2600
69.0 (92.5)
375 (277)
440 (325)
1PH8165-
■
■
F
■
■
-
■
■
■
1
2800
4000
3900
87.0 (116.67)
300 (221)
440 (325)
1PH8165-
■
■
L
■
■
-
■
■
■
1
1750
4000
2600
77.0 (103.26)
420 (310)
500 (369)
1PH8167-
■
■
F
■
■
-
■
■
■
1
2800
4000
4000
98.0 (131.42)
335 (247)
500 (369)
1PH8167-
■
■
L
■
■
-
■
■
■
1
Shaft height 160 – Water cooling – Line voltage 400 V 3 AC, operation on Active Line Module
1750
4000
2400
67.0 (89.85)
365 (269)
440 (325)
1PH8164-
■
■
F
2
■
-
■
■
■
1
2300
4000
4000
93.0 (124.71)
315 (232)
440 (325)
1PH8164-
■
■
L
2
■
-
■
■
■
1
1750
4000
2600
85.0 (113.99)
460 (339)
550 (406)
1PH8166-
■
■
F
2
■
-
■
■
■
1
2300
4000
3900
109 (146.17)
375 (277)
550 (406)
1PH8166-
■
■
L
2
■
-
■
■
■
1
1750
4000
2600
94.0 (126.05)
510 (376)
620 (457)
1PH8168-
■
■
F
2
■
-
■
■
■
1
2300
4000
4000
123 (164.94)
420 (310)
520 (384)
1PH8168-
■
■
L
2
■
-
■
■
■
1
For versions, see
Article No. supplement
and options.
1)
Maximum speed that must not be exceeded, also applies to versions with holding brake.
2)
Maximum permissible operating speed based on the voltage induced in the motor and the voltage stability of the Motor Module
(without protective circuit).
© Siemens AG 2016