SIEMENS
6/128
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M synchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> SH 132 – Forced ventilation/Water cooling
6
■
Selection and ordering data
Rated
speed
Speed,
max.
1)
Operating
speed,
max.
2)
Rated
power
S1
duty
Rated torque
S1
duty
Static torque
SIMOTICS M-1PH8
synchronous motors
n
rated
n
max
n
max, Inv
P
rated
M
rated
M
0
rpm
rpm
rpm
kW (HP)
Nm (lb
f
-ft)
Nm (lb
f
-ft)
Article No.
Shaft height 132 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
1750
4500
2550
18.0 (24.14)
98 (72.3)
105 (77.4)
1PH8131-
77
F
77
-
777
1
2800
4500
4050
27.7 (37.15)
95 (70.1)
105 (77.4)
1PH8131-
77
L
77
-
777
1
1750
4500
3050
23.1 (30.98)
126 (92.9)
131 (96.6)
1PH8133-
77
F
77
-
777
1
2800
4500
3950
35.2 (47.2)
120 (88.5)
131 (96.6)
1PH8133-
77
L
77
-
777
1
1750
4500
2450
27.2 (36.48)
149 (110)
158 (117)
1PH8135-
77
F
77
-
777
1
2300
4500
3500
35.6 (47.74)
148 (110)
158 (117)
1PH8135-
77
G
77
-
777
1
1750
4500
2700
35.6 (47.74)
194 (143)
203 (150)
1PH8137-
77
F
77
-
777
1
2800
4500
3900
53.4 (71.61)
182 (134)
203 (150)
1PH8137-
77
L
77
-
777
1
3300
4500
4500
62.2 (83.41)
180 (133)
203 (150)
1PH8137-
77
M
77
-
777
1
Shaft height 132 – Water cooling – Line voltage 400 V 3 AC, operation on Active Line Module
1750
4500
3150
20.4 (27.36)
112 (82.6)
115 (84.8)
1PH8131-
77
F 2
7
-
777
1
2800
4500
4500
31.7 (42.51)
108 (79.7)
115 (84.8)
1PH8131-
77
L 2
7
-
777
1
1750
4500
2450
26.4 (35.40)
144 (106)
155 (114)
1PH8133-
77
F 2
7
-
777
1
2300
4500
3450
34.9 (46.80)
145 (107)
155 (114)
1PH8133-
77
G 2
7
-
777
1
1750
4500
2650
34.1 (45.7)
186 (137)
196 (145)
1PH8135-
77
F 2
7
-
777
1
2300
4500
3800
44.3 (59.41)
184 (136)
196 (145)
1PH8135-
77
G 2
7
-
777
1
1750
4500
2350
37.0 (49.62)
202 (149)
226 (167)
1PH8137-
77
F 2
7
-
777
1
2300
4500
3500
50.5 (67.72)
212 (156)
226 (167)
1PH8137-
77
G 2
7
-
777
1
1750
4500
3500
52.4 (70.27)
286 (211)
290 (214)
1PH8138-
77
F 2
7
-
777
1
2300
4500
3900
67.7 (90.79)
281 (207)
290 (214)
1PH8138-
77
G 2
7
-
777
1
For versions, see
Article No. supplement
and options.
1)
Maximum speed that must not be exceeded, also applies to versions with holding brake.
2)
Maximum permissible operating speed based on the voltage induced in the motor and the voltage stability of the Motor Module
(without protective circuit).
© Siemens AG 2016