SIEMENS
6/125
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> Terminal box assignment, max. connectable cable cross-sections
6
■
Options
(continued)
Terminal box
type
(See selection
and ordering data
for assignment)
Cable entry
Outer
cable
diameter,
max.
1)
Number of main terminals
Cross-section
per terminal,
max.
Rated
current,
max.
2)
Power
External signals
mm (in)
mm²
A
gk803
1
×
M25
×
1.5
1
×
M16
×
1.5
3)
20 (0.79)
Phases:
3
×
M5
1
×
10
52
Grounding: 2
×
M5
gk813
1
×
M32
×
1.5
1
×
M16
×
1.5
3)
24.2 (0.95)
Phases:
3
×
M5
1
×
16
70
Grounding: 2
×
M5
gk823
1
×
M32
×
1.5
1
×
M16
×
1.5
3)
24.2 (0.95)
Phases:
3
×
M5
1
×
16
70
Grounding: 2
×
M5
gk826
1
×
M32
×
1.5
1
×
M16
×
1.5
3)
24.2 (0.95)
Phases:
6
×
M5
1
×
10
52
Grounding: 2
×
M5
gk833
1
×
M40
×
1.5
1
×
M16
×
1.5
3)
32 (1.26)
Phases:
3
×
M6
1
×
35
110
Grounding: 2
×
M6
gk843
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38 (1.50)
Phases:
3
×
M6
1
×
50
133
Grounding: 2
×
M6
gk846
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38 (1.50)
Phases:
6
×
M6
1
×
25
88
Grounding: 2
×
M6
gk863
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38 (1.50)
Phases:
3
×
M6
1
×
50
133
Grounding: 2
×
M6
gk873
1
×
M63
×
1.5
1
×
M16
×
1.5
3)
42.6 (1.68)
Phases:
3
×
M6
1
×
50
133
Grounding: 2
×
M6
1XB7322-P05
2
×
M50
×
1.5
1
×
M16 × 1.5
4)
38 (1.50)
Phases:
3
×
M12
2
×
50
210
Grounding: 2
×
M6
1XB7422-P06
2
×
M63
×
1.5
1
×
M16 × 1.5
4)
53 (2.09)
Phases:
3
×
M12
2
×
70
270
Grounding: 4
×
M8
1XB7700-P02
3
×
M75
×
1.5
1
×
M16 × 1.5
4)
68 (2.68)
Phases:
3
×
2
×
M12
3
×
150
700
Grounding: 3
×
fixing eyelet
1XB7712-P03
4
×
M75
×
1.5
1
×
M16 × 1.5
4)
68 (2.68)
Phases:
3
×
4
×
M16
4
×
185
1150
Grounding: 4
×
M16
For terminal box type
1XB7712-P01
or
1XB7712-P03
, other cable entries (power) can be ordered
via P options depending on the standard:
P00
P01
P02
P03
P04
Undrilled cable entry plate
Cable entry plate 3 × M63 × 1.5 (not with 1XB7712-P01)
Cable entry plate 3 × M75 × 1.5
Cable entry plate 4 × M75 × 1.5 (not with 1XB7712-P03)
Cable entry plate 4 × M63 × 1.5
For terminal box type
1XB7700-P02
, other cable entries (power) can be ordered
via P options depending on the standard:
P00
P01
Undrilled cable entry plate
Cable entry plate 3 × M63 × 1.5
For terminal box types
1XB7322-P05
and
1XB7422-P06
, another cable entry (power) can be ordered
via the P option depending on the standard:
P00
Undrilled cable entry plate
With option
K09
or
K10
, terminal box
gk873
mounted on the side is used instead of terminal box
gk863
.
With option
K09
or
K10
, terminal box
gk843
mounted on the side is used instead of terminal box
gk833
.
With option
K09
or
K10
, terminal box
gk823
mounted on the side is used instead of terminal box
gk813
.
1)
Dependent on the design of the metric cable gland.
2)
Current-carrying capacity based on EN 60204-1/IEC 60364-5-52 with installation type E.
3)
Thread M16 × 1.5 arranged with 90° to signal connection; thread only with options A12, A25 and when 9th data position is A (without encoder).
4)
Thread M16 × 1.5 arranged opposite the signal connection (lateral to the cable entry plate); thread only with option A12 and when 9th data position
is A (without encoder).
© Siemens AG 2016