Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> Forced ventilation/Water cooling
6
■
Options
(continued)
Order
code
Description of option
For use with motors
When ordering a motor with options,
-Z
must be added to the article number.
The order code should also be specified for each additional required option.
Note:
Order codes must not be repeated in plain text in the order.
Shaft height
80 to 160
Shaft height
180 to 225
Shaft height 280
for water
cooling only
(11th data
position 2)
Shaft height 280
for forced
ventilation only
(11th data
position 1)
L00
Replace terminal box (standard) with the next larger terminal box
(Note dimension implications, see CAD CREATOR.)
–
✔
✔
L02
Fan version for increased vibration resistance
–
✔
L03
Increased vibration stress
–
Only for SH 180
and SH 225
–
L12
Condensation drain hole
–
✔
7)
✔
L27
NDE bearing in insulated version
–
Only for SH 180
Standard
L29
Enhanced corrosion protection for installation in industrial/marine climates
–
On request
✔
L72
Shaft made of special steel
–
–
✔
L74
Fan version with IP65 degree of protection
4)
✔
–
–
L75
Special fan version for 400 V 3 AC with IP65 degree of protection
4)
✔
M03
Version for potentially explosive atmospheres Zone 2
5)
✔
–
–
M39
Version for potentially explosive atmospheres Zone 22
5)
✔
Only for SH 180
and SH 225
–
M83
Additional back-off thread on motor feet (possible if 12th data position is 0 or 3)
–
–
✔
P00
Undrilled cable entry plate
–
✔
✔
P01
Cable entry plate 3 × M63 × 1.5
–
Only for
1XB7700-P02
1XB7712-P03
Only for
1XB7712-P03
P02
Cable entry plate 3 × M75 × 1.5
–
Only for
1XB7712-P03
Only for
1XB7712-P01
1XB7712-P03
P03
Cable entry plate 4 × M75 × 1.5
–
–
Only for
1XB7712-P01
P04
Cable entry plate 4 × M63 × 1.5
–
Only for
1XB7712-P03
Only for
1XB7712-P01
1XB7712-P03
Q00
Extra grounding terminals in terminal box
–
–
✔
Q12
M5 sealing air connection
✔
–
–
Q14
Filter for special fan L75
–
Only for SH 180
and SH 225
–
Q31
Metal rating plate instead of adhesive label
✔
✔
✔
U60
Holding brake 230 V
✔
–
–
U61
Holding brake 230 V with micro switch
✔
–
–
U62
Holding brake 230 V with manual brake release lever
✔
–
–
U63
Holding brake 230 V with micro switch and manual brake release lever
✔
Only for SH 180
and SH 225
–
U65
Holding brake 24 V DC
✔
–
–
U66
Holding brake 24 V DC with micro switch
✔
–
–
U67
Holding brake 24 V DC with manual brake release lever
✔
–
–
U68
Holding brake 24 V DC with micro switch and manual brake release lever
✔
–
–
✔
Option available
–
Option not available
4)
Regardless of the degree of protection, at high levels of atmospheric pollution, the fan must be cleaned.
5)
Not in combination with the following bearings (14th data position): A, F, L, M, N, P.
6)
Only with direction of air flow NDE
DE (11th digit in MLFB = 1).
7)
Standard for water-cooled motors.
© Siemens AG 2016