Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> Forced ventilation/Water cooling
6
■
Options
Order
code
Description of option
For use with motors
When ordering a motor with options,
-Z
must be added to the article number.
The order code should also be specified for each additional required option.
Note:
Order codes must not be repeated in plain text in the order.
Shaft height
80 to 160
Shaft height
180 to 225
Shaft height 280
for water
cooling only
(11th data
position 2)
Shaft height 280
for forced
ventilation only
(11th data
position 1)
A12
Additional PTC thermistor chain for alarm and tripping
(Only
possible for version with terminal box)
✔
✔
✔
A25
Additional KTY84 temperature sensor as reserve connected to signal terminal strip
(Only
possible for version with terminal box)
✔
Standard
Standard
B02
Test certificate (for ordered motor)
✔
Standard
Standard
G00
External fan NDE left
, air inlet at NDE (possible if 15th data position is U, W or X)
–
–
✔
G02
External fan NDE right
, air inlet at NDE (possible if 15th data position is V, W or X)
–
–
✔
G06
External fan DE left
, air inlet at NDE (possible if 15th data position is U, V or W)
–
–
✔
G07
External fan DE left
, air inlet at DE (possible if 15th data position is U, V or W)
–
–
✔
G08
External fan DE right
, air inlet at NDE (possible if 15th data position is U, V or W)
–
–
✔
G09
External fan DE right
, air inlet at DE (possible if 15th data position is U, V or W)
–
–
✔
G11
External fan DE top
, air inlet at DE (possible if 15th data position is U, V or W)
–
–
✔
G14
With air filter (only
possible if 11th data position is 1)
Only for SH 132
and SH 160
✔
✔
G50
M8 thread for sensor mounting (e.g. acceleration sensor for bearing condition monitoring)
–
–
✔
K08
Encoder connector or DRIVE-CLiQ mounted opposite
(not possible when 15th data position is X)
–
✔
✔
K09
Terminal box or power connector NDE on the right
Only for
SH 100
1)
to
SH 160
–
–
Terminal box NDE on the right
, cable entry DE, signal connection at top
(only possible if 15th data position is A)
–
✔
–
K10
Terminal box or power connector NDE on the left
Only for
SH 100
1)
to
SH 160
–
–
Terminal box NDE on the left
, cable entry DE, signal connection at top
(only possible if 15th data position is A)
–
✔
–
K16
Second shaft extension (SH 280 d × l: 95 mm (3.74 in) x 170 mm (6.69 in)
(possible if 9th data position is A and 12th data position is 0 or 3)
–
–
✔
K17
Labyrinth seal DE for Performance bearings (14th data position is L)
Only for SH 180
–
–
K18
Radial shaft sealing ring DE
2)
(not
possible for version with holding brake)
✔
✔
–
K40
Regreasing system, DE and NDE
–
Only for SH 180
and SH 225
Standard
K45
Anti-condensation heating 230 V AC
–
✔
✔
K69
Pipe connection prepared NDE right
(only
possible with forced ventilation,
not with G00, G02, G06, G07, G08, G09, G11, G14 and L02)
–
–
✔
K70
Pipe connection prepared NDE left
(only
possible with forced ventilation,
not with G00, G02, G06, G07, G08, G09, G11, G14 and L02)
–
–
✔
K71
Pipe connection prepared NDE top
(only
possible with forced ventilation,
not with G00, G02, G06, G07, G08, G09, G11, G14 and L02)
–
–
✔
K80
Axial pipe connection NDE (only
possible with forced ventilation)
✔
Only for SH 180
and SH 225
Options K69,
K70, K71
K83
Rotation of terminal box by +90 degrees (possible in combination with options K09
or K10 or if 15th data position is U, V or W)
–
✔
3)
✔
K84
Rotation of terminal box by -90 degrees (possible in combination with
options K09 or K10 or if 15th data position is U, V, W or X)
–
✔
3)
✔
K85
Rotation of terminal box by +180 degrees (possible in combination with
options K09 or K10 or if 15th data position is U, V, W or X)
–
✔
✔
K90
Version with flange size A400 (possible if 12th data position is 2, 3 or 5)
–
Only for SH 180
–
✔
Option available
–
Option not available
1)
Not possible when 12th data position is 2 (type of construction IM B5).
2)
Only appropriate if oil spray or oil vapor is occasionally deposited on the sealing ring. Radial shaft sealing ring not possible when:
14th data position is E, F, L, M or N.
3)
Not possible with 1PH822 and terminal box 1XB7712-P03.