SIEMENS
6/121
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8 without holding brake – Article No. supplement
> SH 280 – Forced ventilation
6
■
Selection and ordering data
Position of the Article No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Shaft height 280
(only forced ventilation)
1
P
H
8
2
8
.
–
1
.
1
–
1
–
Z
Overall length
Asynchronous version
without brake
1
Encoder systems for motors without
DRIVE-CLiQ interface
Without encoder
A
Incremental encoder sin/cos 1
V
pp
2048 S/R with C and D tracks (encoder IC2048S/R)
M
Absolute encoder 2048 S/R, 4096 revolutions, multi-turn,
with EnDat interface (encoder AM2048S/R)
E
Encoder systems for motors with
DRIVE-CLiQ interface
Incremental encoder 22 bit (resolution 4194304, internal 2048 S/R)
+ commutation position 11 bit (encoder IC22DQ)
D
Absolute encoder 22 bit + 12 bit multi-turn (encoder AM22DQ)
F
Rated speed
(winding version)
Cooling
Degree of protection
Forced ventilation
IP55
1
Type of construction
IM B3 (IM V6)
0
IM V5
1)
1
IM B5 with flange A660 (IM V3)
1)
2
IM B35 with flange A660 (IM V35)
3
IM V15 with flange A660
1)
5
Shaft extension DE
Balancing
Plain shaft
–
0
Feather key
Full-key
1
Feather key
Half-key
2
Bearing version
Vibration severity acc. to
Siemens
2)
/EN 60034-14
Shaft and
flange accuracy
Standard
R/A
R
B
Increased radial forces
R/A
R
F
Power connection
(looking at DE)
Cable
entry
Signal
connection
External fan NDE
Air inlet from NDE,
air-flow direction NDE
DE
Terminal box NDE right
Bottom
DE
Top
U
Left
(order code
G00
required)
U
–
Z
Terminal box NDE left
Bottom
DE
Top
V
Right
(order code
G02
required)
V
–
Z
Terminal box NDE top
Right
DE
Left
(order code
G00
required)
W
–
Z
Right
(order code
G02
required)
W
–
Z
Terminal box DE top
3)
Right
NDE
Top
3)4)
X
Left
3)
(order code
G00
required)
X
–
Z
Right
3)
(order code
G02
required)
X
–
Z
Version status
1
Special version
(order codes required for options)
Z
1)
Only possible when 14th data position is B (Standard bearings).
2)
For definition of the vibration severity according to Siemens, see 1PH8 Motors Configuration Manual.
3)
Only possible when 12th data position is 0 (type of construction IM B3) or 1 (type of construction IM V5).
4)
Only possible for assignment with terminal box 1XB7712-P..
© Siemens AG 2016