SIEMENS
6/118
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8 without holding brake – Article No. supplement
> SH 80 to SH 160 – Forced ventilation/Water cooling
6
■
Selection and ordering data
Position of the Article No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Shaft height 80
1
P
H
8
0
8
.
–
1
.
–
1
–
Z
Shaft height 100
1
P
H
8
1
0
.
–
1
.
–
1
–
Z
Shaft height 132
1
P
H
8
1
3
.
–
1
.
–
1
–
Z
Shaft height 160
1
P
H
8
1
6
.
–
1
.
–
1
–
Z
Overall length
Asynchronous version
without brake
1
Encoder systems for motors without
DRIVE-CLiQ interface
Without encoder
A
Incremental encoder sin/cos 1
V
pp
2048 S/R with C and D tracks (encoder IC2048S/R)
1)
M
Incremental encoder sin/cos 1
V
pp
512 S/R without C and D tracks (encoder IN256S/R)
2)
T
Incremental encoder sin/cos 1
V
pp
256 S/R without C and D tracks (encoder IN256S/R)
3)
C
Absolute encoder 2048 S/R, 4096 revolutions, multi-turn,
with EnDat interface (encoder AM2048S/R)
1)
E
Encoder systems for motors with
DRIVE-CLiQ interface
Incremental encoder 22 bit (resolution 4194304, internal 2048 S/R)
+ commutation position 11 bit (encoder IC22DQ)
1)
D
Incremental encoder 20 bit (resolution 1048576, internal 512 S/R)
2)
without commutation position (encoder IN20DQ)
U
Incremental encoder 19 bit without commutation position (encoder IN19DQ)
3)
S
Absolute encoder 22 bit + 12 bit multi-turn (encoder AM22DQ)
1)
F
Rated speed
(winding version)
Cooling
Degree of protection
Forced ventilation DE
NDE
IP55
0
Forced ventilation NDE
DE
IP55
1
Water cooling
IP65
2
Type of construction
IM B3 (IM V5, IM V6)
0
IM B5 (IM V1, IM V3) (Not
possible for 1PH816 and when 14th data position is L or M)
2
IM B35 (IM V15, IM V35) (Only
possible for 1PH810/1PH813/1PH816)
3
Shaft extension DE
Balancing
Plain shaft
–
0
Feather key (not
possible when 14th data position is M)
Full-key
1
Feather key (not
possible when 14th data position is M)
Half-key
2
Plain hollow shaft
3)
–
3
Bearing version
Vibration severity acc. to
Siemens
4)
/EN 60034-14
Shaft and
flange accuracy
Standard with location bearing
8)
R/A
R
B
Standard with location bearing
8)
S/A
R
C
Standard with location bearing
8)
SR/A
R
D
Standard
8)
R/A
R
G
Standard
8)
S/A
R
H
Increased radial forces
8)
R/A
R
F
Performance
5)6)
SPECIAL/B
SPECIAL
L
High Performance
6)7)
SPECIAL/B
SPECIAL
M
Advanced Lifetime
8)9)
S/A
R
Q
Power connection
(looking at DE)
Cable entry
Signal connection
Terminal box top
Right
DE
A
Terminal box top
Left
DE
B
Terminal box top
NDE
Left
C
Terminal box top
DE
Left
D
Power connector top
8)10)
Right
DE
E
Power connector top
8)10)
Left
DE
F
Power connector top
8)10)
NDE
Left
G
Power connector top
8)10)
DE
Right
H
Version status
1
Special version
(order codes required for options)
Z
1)
Limited to
n
max
= 12000 rpm.
2)
Limited to
n
max
= 15000 rpm.
3)
Only possible when 14th data position is L, M or 9. Data position C, S.
4)
For definition of the vibration severity according to Siemens, see 1PH8
Motors Configuration Manual.
5)
For 1PH808 limited to
n
max
= 15000 rpm.
For 1PH810 limited to
n
max
= 12000 rpm.
For 1PH813 limited to
n
max
= 10000 rpm.
For 1PH816 limited to
n
max
= 9000 rpm.
6)
Not possible for 1PH816 when 12th data position is 2
(type of construction IM B5).
7)
For 1PH808 limited to
n
max
= 20000 rpm. For 1PH810 limited to
n
max
= 18000 rpm. For 1PH813 limited to
n
max
= 15000 rpm.
For 1PH816 limited to
n
max
= 10000 rpm.
8)
Not possible when 9th data position is T, U.
9)
For 1PH808/1PH810 limited to
n
max
= 5000 rpm.
For 1PH813 limited to
n
max
= 4500 rpm.
For 1PH816 limited to
n
max
= 4000 rpm.
10)
Power connector for 1PH810 only possible up to a maximum
stall current of
I
0
= 36 A.
Power connector for 1PH813 only possible up to a maximum
stall current of
I
0
= 85 A. Power connector not possible for 1PH816.
© Siemens AG 2016