SIEMENS
6/117
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8 with holding brake – Article No. supplement
> SH 80 to SH 160 – Forced ventilation/Water cooling
6
■
Selection and ordering data
Position of the Article No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Shaft height 80
1
P
H
8
0
8
.
–
3
.
–
1
–
Z
Shaft height 100
1
P
H
8
1
0
.
–
3
.
–
1
–
Z
Shaft height 132
1
P
H
8
1
3
.
–
3
.
–
1
–
Z
Shaft height 160
1
P
H
8
1
6
.
–
3
.
–
1
–
Z
Overall length
Asynchronous version
with holding brake
1)
3
Encoder systems for motors without
DRIVE-CLiQ interface
Without encoder
A
Absolute encoder EnDat 2048 S/R (encoder AM2048S/R)
with EnDat interface (encoder AM2048S/R)
E
Incremental encoder sin/cos 1
V
pp
2048 S/R with C and D tracks (encoder IC2048S/R)
M
Encoder systems for motors with
DRIVE-CLiQ interface
Absolute encoder 22 bit single-turn + 12 bit multi-turn (encoder AM22DQ)
F
Incremental encoder 22 bit with commutation position (encoder IC22DQ)
D
Rated speed
(winding version)
Cooling
Degree of protection
Forced ventilation DE
NDE
IP55
0
Forced ventilation NDE
DE
IP55
1
Water cooling
IP55
2)
2
Type of construction
IM B5 (IM V1, IM V3)
3)
2
IM B35 ( IM V15, IM V35)
4)
3
Shaft extension DE
Balancing
Plain shaft
–
0
Feather key
Half-key
2
Bearing version
Vibration severity acc. to
Siemens
5)
/EN 60034-14
Shaft and
flange accuracy
Standard
A
N
A
Advanced Lifetime
A
N
P
Power connection
6)
(looking at DE)
Cable entry
Signal connection
Terminal box top
Right
DE
A
Terminal box top
Left
DE
B
Terminal box top
NDE
Left
C
Terminal box top
DE
Left
D
Power connector top
7)
Right
DE
E
Power connector top
7)
Left
DE
F
Power connector top
7)
NDE
Left
G
Power connector top
7)
DE
Left
H
Version status
1
Brake versions
Brake supply voltage
Holding brake DE
U60
230 V 1 AC 50/60 Hz
Holding brake DE with micro switch
U61
Holding brake DE with manual brake release lever
U62
Holding brake DE with micro switch and manual brake release lever
U63
Brake supply voltage
Holding brake DE
U65
24 V DC
Holding brake DE with micro switch
U66
Holding brake DE with manual brake release lever
U67
Holding brake DE with micro switch and manual brake release lever
U68
Z options that cannot be combined with holding brake DE: K18, M03, M39
1)
A U option must also be stated in the order to specify the holding brake
version.
Shaft height 80: limited to
n
max
= 5000 rpm.
Shaft height 100: limited to
n
max
= 5000 rpm.
Shaft height 132: limited to
n
max
= 4500 rpm.
Shaft height 160: limited to
n
max
= 4000 rpm.
2)
The degree of protection is limited to IP55 as a result of the holding brake.
3)
Not possible with shaft height 160.
4)
Not possible with shaft height 80.
5)
For a definition of the vibration severity according to Siemens, refer to the
1PH8 Motors Configuration Manual.
6)
Holding brake can only be connected via terminal box top.
7)
Power connector for motor only (not with holding brake):
Power connector for shaft height 100 only possible up to a maximum
stall current of
I
0
= 36 A.
Power connector for shaft height 132 only possible up to a maximum
stall current of
I
0
= 85 A.
Power connector not possible for shaft height 160.
© Siemens AG 2016