SIEMENS
6/108
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> SH 100/SH 132 – Forced ventilation
6
■
Selection and ordering data
Rated
speed
Continuous speed,
max.
1)
Operating
speed
during field
weakening
1)5)
Rated
power
Rated
torque
Static torque
SIMOTICS M-1PH8
asynchronous motors
Y/
∆
Y/
∆
Y/
∆
∆
Y/
∆
Y/
∆
Y/
∆
Y/
∆
n
rated
n
max1
2)
n
max2
3)
n
max3
4)
n
2
P
rated
M
rated
M
0
rpm
rpm
rpm
rpm
rpm
kW (HP)
Nm (lb
f
-ft)
Nm (lb
f
-ft)
Article No.
Shaft height 100 – Forced ventilation – Star/delta circuit – Line voltage 400 V 3 AC, operation on Active Line Module
2000/5000
9000
12000
18000
8950/10000
4.9/4.9 (6.57/6.57)
23/9 (17.0/6.64)
29/19 (21.4/14.0)
1PH8101-1
7
S
77
-
777
1
9000
12000
18000
7650/10000
10/9.3 (13.4/12.5)
48/18 (35.4/13.3)
55/36 (40.6/26.6)
1PH8105-1
7
S
77
-
777
1
9000
12000
18000
8550/10000
11/11 (14.8/14.8)
53/21 (39.1/15.5)
63/42 (46.5/31.0)
1PH8107-1
7
S
77
-
777
1
Shaft height 132 – Forced ventilation – Star/delta circuit – Line voltage 400 V 3 AC, operation on Active Line Module
2000/5000
8000
10000
15000
8000/10000
14.6/14.6 (19.6/19.6)
70/28 (51.6/20.7)
94/55 (69.3/40.6)
1PH8131-1
7
S
77
-
777
1
8000
10000
15000
6500/10000
24.5/24.5 (32.9/32.9)
117/47 (86.3/34.7)
157/94 (116/69.3)
1PH8135-1
7
S
77
-
777
1
8000
10000
15000
3000/6000
29/27.5 (38.9/36.9)
138/53 (102/39.1)
185/105 (136/77.4)
1PH8137-1
7
S
77
-
777
1
For versions, see
Article No. supplement
and options.
1)
Speed data are based on an infeed with Active Line Module (see characteristic curves); the maximum speed of the encoders must be observed.
2)
Bearing version for Standard (14th data position is B to H); reduced values for type F, see 1PH8 Configuration Manual.
3)
Bearing version for Performance (14th data position is L).
4)
Bearing version for High Performance (14th data position is M).
5)
n
2
: max. permissible thermal speed at constant output or speed, which is at the voltage limit when
P
=
P
rated.
© Siemens AG 2016