SIEMENS
6/104
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> SH 80 to SH 160 – Forced ventilation
6
■
Selection and ordering data
Rated
speed
Continuous speed, max.
1)
Operating
speed
during field
weakening
1)5)
Rated
power
Rated
torque
Static
torque
SIMOTICS M-1PH8
asynchronous motors
With
holding
brake
Without
holding
brake
n
rated
n
max, Br
n
max1
2)
n
max2
3)
n
max3
4)
n
2
P
rated
M
rated
M
0
rpm
rpm
rpm
rpm
rpm
rpm
kW (HP)
Nm (lb
f
-ft)
Nm (lb
f
-ft)
Article No.
Shaft height 80 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
1750
2300
3300
5000
5000
5000
5000
–
10000
10000
10000
10000
12000
15000
15000
15000
–
17000
20000
20000
5200
10550
16500
20000
3.3 (4.43)
4.1 (5.50)
4.5 (6.03)
5.3 (7.11)
18 (13.3)
17 (12.5)
13 (9.59)
10 (7.38)
21 (15.5)
21 (15.5)
21 (15.5)
19 (14.0)
1PH8083-
77
F
77
-
777
1
1PH8083-
77
G
77
-
777
1
1PH8083-
77
M
77
-
777
1
1PH8083- 1
7
N
77
-
777
1
1750
2300
3300
5000
5000
5000
5000
–
10000
10000
10000
10000
14000
15000
15000
15000
–
18000
20000
20000
5850
9650
19400
20000
4.3 (5.77)
5.4 (7.24)
5.2 (6.97)
6.5 (8.72)
23 (17.0)
22 (16.2)
15 (11.1)
12 (8.85)
27 (19.9)
27 (19.9)
27 (19.9)
25 (18.4)
1PH8087-
77
F
77
-
777
1
1PH8087-
77
G
77
-
777
1
1PH8087-
77
M
77
-
777
1
1PH8087- 1
7
N
77
-
777
1
Shaft height 100 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
1750
5000
9000
12000
–
5000
4.3 (5.77)
23 (17.0)
29 (21.4)
1PH8101-
77
F
77
-
777
1
1150
1750
2300
3300
5000
5000
5000
5000
9000
9000
9000
9000
12000
12000
12000
12000
–
–
–
18000
2450
4000
6000
16000
4.3 (5.77)
6.3 (8.45)
7.5 (10.06)
9.3 (12.47)
36 (26.6)
34 (25.1)
31 (22.9)
27 (19.9)
38 (28.0)
38 (28.0)
38 (28.0)
38 (28.0)
1PH8103-
77
D
77
-
777
1
1PH8103-
77
F
77
-
777
1
1PH8103-
77
G
77
-
777
1
1PH8103-
77
M
77
-
777
1
1750
5000
9000
12000
–
5900
8.0 (10.73)
44 (32.5)
52 (38.4)
1PH8105-
77
F
77
-
777
1
500
1150
1750
2300
3300
5000
5000
5000
5000
5000
7000
9000
9000
9000
9000
–
12000
12000
12000
12000
–
–
–
–
18000
1500
4750
4600
7500
18000
3.2 (4.29)
7.2 (9.66)
10.0 (13.41)
12.0 (16.1)
13.0 (17.43)
61 (45)
60 (44.3)
55 (40.6)
50 (36.9)
38 (28.0)
62 (45.7)
63 (46.5)
63 (46.5)
63 (46.5)
59 (43.5)
1PH8107-
77
B
77
-
777
1
1PH8107-
77
D
77
-
777
1
1PH8107-
77
F
77
-
777
1
1PH8107-
77
G
77
-
777
1
1PH8107-
77
M
77
-
777
1
Shaft height 132 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
500
1750
4500
4500
6000
8000
–
10000
–
11000
1500
5150
3.6 (4.83)
13.0 (17.43)
69 (50.9)
71 (52.4)
76 (56.1)
96 (70.8)
1PH8131-
77
B
77
-
777
1
1PH8131-
77
F
77
-
777
1
500
1150
1750
2300
4500
4500
4500
4500
6000
8000
8000
8000
–
10000
10000
10000
–
–
13000
15000
1200
3000
5000
6500
6.5 (8.72)
13.5 (18.10)
17.5 (23.47)
22.5 (30.7)
124 (91.5)
112 (82.6)
96 (70.8)
93 (68.6)
124 (91.5)
128 (94.4)
126 (92.9)
126 (92.9)
1PH8133-
77
B
77
-
777
1
1PH8133-
77
D
77
-
777
1
1PH8133-
77
F
77
-
777
1
1PH8133-
77
G
77
-
777
1
500
1750
4500
4500
6000
8000
–
10000
–
14000
1200
5500
8.0 (10.73)
21.5 (28.83)
153 (113)
118 (87.0)
162 (119)
157 (116)
1PH8135-
77
B
77
-
777
1
1PH8135-
77
F
77
-
777
1
500
1150
1750
2300
4500
4500
4500
4500
6000
8000
8000
8000
–
10000
10000
10000
–
12000
15000
15000
1400
4000
5000
5000
8.6 (11.3)
19.5 (26.15)
22.0 (29.5)
29.0 (38.89)
165 (122)
162 (119)
140 (103)
120 (88.5)
171 (126)
183 (135)
172 (127)
176 (130)
1PH8137-
77
B
77
-
777
1
1PH8137-
77
D
77
-
777
1
1PH8137-
77
F
77
-
777
1
1PH8137-
77
G
77
-
777
1
Shaft height 160 – Forced ventilation – Line voltage 400 V 3 AC, operation on Active Line Module
500
1150
1750
2300
4000
4000
4000
4000
6500
6500
6500
6500
–
9000
9000
9000
–
10000
10000
10000
2200
3550
3050
3200
12.0 (16.1)
25.0 (33.53)
34.0 (45.59)
38.0 (50.96)
229 (169)
208 (153)
186 (137)
158 (117)
253 (187)
243 (179)
252 (186)
254 (187)
1PH8163-
77
B
77
-
777
1
1PH8163-
77
D
77
-
777
1
1PH8163-
77
F
77
-
777
1
1PH8163-
77
G
77
-
777
1
500
1150
1750
2300
4000
4000
4000
4000
6500
6500
6500
6500
–
9000
9000
9000
–
10000
10000
10000
1850
4850
2650
3000
16.0 (21.46)
31.0 (41.57)
41.0 (54.98)
44.0 (59)
306 (226)
257 (190)
224 (165)
183 (135)
329 (243)
302 (223)
304 (224)
302 (223)
1PH8165-
77
B
77
-
777
1
1PH8165-
77
D
77
-
777
1
1PH8165-
77
F
77
-
777
1
1PH8165-
77
G
77
-
777
1
For versions, see
Article No. supplement
and options.
1)
Speed data are based on an infeed with Active Line Module (see characteristic curves); the maximum speed of the encoders must be observed.
2)
Bearing version for Standard (14th data position is B to H); reduced values for type F, see 1PH8 Configuration Manual.
3)
Bearing version for Performance (14th data position is L).
4)
Bearing version for High Performance (14th data position is M).
5)
n
2
: max. permissible thermal speed at constant output or speed, which is at the voltage limit when
P
=
P
rated.
© Siemens AG 2016