SIEMENS
7/8
Siemens NC 62 · 2016
MOTION-CONNECT connection systems
Power cables for SINAMICS S120
7
■
Technical specifications
Degree of protection of pre-assembled power cables and their extensions when closed and connected: IP67.
Power cables
MOTION-CONNECT 500
MOTION-CONNECT 800PLUS
6FX500.-
.....
-
....
6FX800.-
.....
-
....
Certificate of suitability
• VDE
1)
Yes
Yes
• cURus or UR/CSA
UL 758, CSA-C22.2-N.210.2-M90
UL 758, CSA-C22.2-N.210.2-M90
• UR-CSA File No.
2)
Yes
Yes
• RoHS conformity
Yes
Yes
Rated voltage
V
0
/
V
in accordance with
EN 50395
• Power conductors
600 V/1000 V
600 V/1000 V
• Signal conductors
24 V (EN) 1000 V (UL/CSA)
24 V (EN) 1000 V (UL/CSA)
Test voltage, rms
• Power conductors
4 kV
4 kV
• Signal conductors
2 kV
2 kV
Operating temperature on the surface
• Fixed installation
-20 … +80 °C (-4 ... +176 °F)
-50 … +80 °C (-58 ... +176 °F)
• Flexible installation
0 … 60 °C (32 ... 140 °F)
-20 … +60 °C (-4 ... +140 °F)
Tensile stress, max.
• Fixed installation
50 N/mm
2
(7252 lb
f
/in
2
)
50 N/mm
2
(7252 lb
f
/in
2
)
• Flexible installation
20 N/mm
2
(2901 lb
f
/in
2
)
20 N/mm
2
(2901 lb
f
/in
2
)
Smallest bending radius
• Fixed installation
5
×
D
max
4
×
D
max
• Flexible installation
See selection and ordering data
See selection and ordering data
Torsional stress
Absolute 30°/m
Absolute 30°/m
Bending
100000
10 million
Traversing velocity
30 m/min (98.4 ft/min)
Up to 300 m/min (984 ft/min)
Acceleration
2 m/s
2
(6.56 ft/s
2
)
Up to 50 m/s
2
(164 ft/s
2
),
see characteristics on page 7/5
Insulation material, incl. jacket
CFC/silicone-free
CFC/halogen/silicone-free
IEC 60754-1/DIN VDE 0472-815
Oil resistance
EN 60811-2-1 (mineral oil only)
EN 60811-2-1
Outer jacket
PVC
PUR, HD22.10 S2 (VDE 0282, Part 10)
DESINA color orange RAL 2003
DESINA color orange RAL 2003
Flame-retardant
EN 60332-1-1 to 1-3
EN 60332-1-1 to 1-3
1)
The respective registration number is printed on the cable jacket (only applies to power cables).
2)
The File No. is printed on the cable jacket.
© Siemens AG 2016