SIEMENS
6/157
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH2 asynchronous built-in motors for direct drive – Water cooling
6
■
Characteristic curves
Typical speed/power graph for AC motors
1)
The graph shows the typical relationship between motor speed
and drive power for SIMOTICS M-1PH2 motors for the following
duty types in accordance with IEC 60034-1:
S1:
Continuous duty
S6:
Continuous duty with intermittent load and a relative duty
factor of 60 % (S6-60 %) or 40 % (S6-40 %) with a maximum
duty cycle time of 10 minutes.
1)
For further configuration information, see the SIMOTICS M-1PH2 Motors
Configuration Manual.
2)
Values indicated by the speed/power graph are valid in systems with an
Active Line Module and a 400 V 3 AC supply system.
If you are using a Smart Line Module, proceed in accordance with the
SIMOTICS M-1PH2 Motors Configuration Manual.
S6-40 %
S6-60 %
S1
0
0
n
2
S6-40 %
n
2
S6
-
60 %
n
2
S1
P
n
max
Motor power
Speed
Voltage limit
n
rated
G_NC01_EN_00016b
SIMOTICS M-1PH2
built-in motor
Rated
speed
Attainable speed at rated power
in duty type
Type
n
rated
n
2
2)
rpm
S1
rpm
S6-60 %
rpm
S6-40 %
rpm
1PH2093
1PH2095
1500
4700
4000
4200
3600
3900
3300
1PH2113
1PH2115
1PH2117
1PH2118
1500
5400
4500
4700
5000
4800
4100
4200
4500
4400
3700
3800
4100
© Siemens AG 2016