SIEMENS
6/155
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M synchronous motors for SINAMICS S120
Standard-type SIMOTICS M-1FE2 synchronous built-in motors – Water cooling
6
Motor type
(repeated)
Rated current for duty type
Voltage Protection
Module (VPM)
SINAMICS S120 Motor Module
Quantity
Motor Modules
Required
rated current
Booksize format
For other versions
and components,
see SINAMICS S120
drive system
I
rated
I
rated
S1
S6-40 %
S1 to
n
max
A
A
A
Article No.
1FE2182-8LH...
145
214
VPM 200
1
200
6SL312
7
-1TE32-0AA.
1FE2182-8LN...
73
108
VPM 120
1
85
6SL312
7
-1TE28-5AA.
1FE2183-8LH...
189
278
VPM 200
1
200
6SL312
7
-1TE32-0AA.
1FE2183-8LN...
95
140
VPM 200
1
132
6SL312
7
-1TE31-3AA.
1FE2184-8LH...
225
333
2 × VPM 200
2
2 × 132
6SL312
7
-1TE31-3AA.
1FE2184-8LK...
190
280
VPM 200
1
200
6SL312
7
-1TE32-0AA.
1FE2184-8LN...
114
168
VPM 200
1
132
6SL312
7
-1TE31-3AA.
1FE2185-8LH...
250
368
2 × VPM 200
2
2 × 132
6SL312
7
-1TE31-3AA.
1FE2185-8LL...
189
278
VPM 200
1
200
6SL312
7
-1TE32-0AA.
1FE2185-8LN...
132
194
VPM 200
1
132
6SL312
7
-1TE31-3AA.
1FE2186-8LH...
290
424
2 × VPM 200
2
2 × 200
6SL312
7
-1TE32-0AA.
1FE2186-8LM...
192
283
VPM 200
1
200
6SL312
7
-1TE32-0AA.
1FE2186-8LN...
154
227
VPM 200
1
200
6SL312
7
-1TE32-0AA.
1FE2187-8LH...
325
479
2 × VPM 200
2
2 × 200
6SL312
7
-1TE32-0AA.
1FE2187-8LN...
190
280
VPM 200
1
200
6SL312
7
-1TE32-0AA.
Cooling:
Internal air cooling
External air cooling
0
1
1)
Standard scope of supply: Impregnated winding with 2 × KTY (1 × reserve).
2)
Full protection option, application example: Load at motor standstill, external tripping unit required: Article No.: 3RN1013-1GW10.
3)
Universal protection option: Full protection + NTC PT3-51F + NTC K227.
4)
Ordering spare parts: Stator: 1FE2…-…..-2...
5)
Ordering spare parts: Rotor: 1FE2…-…..-3...
6)
For cable design, see Configuration Manual, standard cable length = 0.5 m (1.64 ft).
7)
Standard rotor is not pre-balanced.
8)
Not for 1FE2187-8LH.
© Siemens AG 2016