SIEMENS
2/54
Siemens NC 62 · 2016
SINUMERIK CNC
Functions
Programmable logic controller PLC
2
Programmable logic controller PLC
Expansion of the PLC user memory
by 128 KB each
6FC5800-0AD10-0YB0
D11... D18
O
O
PLC user memory, maximum
1536 KB
1536 KB
SIMATIC S7-300 PLC 317F-3PN/DP integrated
Processing time for:
• bit operations, minimum
0.025 μs
0.025 μs
• word operations, minimum
0.03 μs
0.03 μs
SIMATIC STEP 7 programming language:
• Ladder diagram LAD
O
O
• Function block diagram FBD
O
O
• Statement list STL
O
O
• Structured Control Language SCL
Add-on package for
SIMATIC STEP 7.
O
O
• Continuous Function Chart CFC
Add-on package for
SIMATIC STEP 7.
O
O
• GRAPH
Add-on package for
SIMATIC STEP 7.
O
O
PLC programming with HiGraph
Add-on package for
SIMATIC STEP 7.
O
O
Distributed I/O via PROFIBUS DP:
See Catalog ST 70 or
Siemens Industry Mall.
• Via integrated interface, data transfer rate up to
12 Mbit/s
12 Mbit/s
• Distributed PROFIBUS DP slaves, maximum number
In total on DP1 and DP2.
124
124
Distributed I/O via PROFINET:
See Catalog ST 70 or
Siemens Industry Mall.
• Via integrated interface,
data transfer rate up to
100 Mbit/s
100 Mbit/s
• Distributed PROFINET slaves, maximum number
128
128
PROFINET CBA
PROFINET IO controller
PROFINET IO device
Number of digital inputs can be adjusted
between 0 and 4049 bytes
Number =
process image inputs.
1024 bytes
1024 bytes
Number of digital outputs can be adjusted
between 0 and 4049 bytes
Number =
process image outputs.
1024 bytes
1024 bytes
I/O inputs, number:
Logical address
range inputs.
8192 bytes
8192 bytes
• Usable, maximum
5700 bytes
5700 bytes
I/O outputs, number:
Logical address
range inputs.
8192 bytes
8192 bytes
• Usable, maximum
5700 bytes
5700 bytes
Bit memories, number
4096 bytes
4096 bytes
Timers, number
512
512
Counters, number
512
512
Description
Instructions
(footnotes are applicable
line by line)
Article No.
Order
code
SINUMERIK
Basic version
O Option
– Not available
Type
840DE sl
840D sl
© Siemens AG 2016