SIEMENS
6/21
Siemens NC 62 · 2016
Feed motors
SIMOTICS S servomotors for SINAMICS S120
SIMOTICS S-1FT7 Compact
> Core type – Natural cooling
6
Motor type
(repeated)
Effi-
ciency
4)
Stall
current
Calculated
power
P
calc
7)
SINAMICS S120 Motor Module
Power cable with complete shield
Motor connection (and brake connection)
via power connector
Rated
output
current
5)
Booksize format
For other versions
and components,
see SINAMICS S120
drive system
η
I
0
at
M
0
∆
T
=100 K
P
calc
at
M
0
∆
T
=100 K
I
rated
Power
connector
Cable
cross-
section
6)
Pre-assembled
cable
%
A
kW (HP)
A
Article No.
Size
mm
2
Article No.
1FT7102-1AC7...
1FT7105-1AC7...
93
93
12.5
18
6.28 (8.42)
10.47 (14)
18
18
6SL312
7
-
7
TE21-8AA.
6SL312
7
-
7
TE21-8AA.
1.5
1.5
4
×
1.5
4
×
2.5
6FX
7
002-5
7
N21-
....
6FX
7
002-5
7
N31-
....
1FT7044-1AF7...
92
2.8
1.57 (2.11)
3
6SL312
7
-
7
TE13-0AA.
1
4
×
1.5
6FX
7
002-5
7
N01-
....
1FT7062-1AF7...
1FT7064-1AF7...
91
93
3.9
5.7
1.88 (2.52)
2.83 (3.8)
5
9
6SL312
7
-
7
TE15-0AA.
6SL312
7
-
7
TE21-0AA.
1
1
4
×
1.5
4
×
1.5
6FX
7
002-5
7
N01-
....
6FX
7
002-5
7
N01-
....
1FT7082-1AF7...
1FT7084-1AF7...
1FT7086-1AF7...
93
93
93
7.6
11
15.5
4.08 (5.47)
6.28 (8.42)
8.8 (11.8)
9
18
18
6SL312
7
-
7
TE21-0AA.
6SL312
7
-
7
TE21-8AA.
6SL312
7
-
7
TE21-8AA.
1
1
1.5
4
×
1.5
4
×
1.5
4
×
2.5
6FX
7
002-5
7
N01-
....
6FX
7
002-5
7
N01-
....
6FX
7
002-5
7
N31-
....
1FT7084-1AH7...
1FT7086-1AH7...
93
91
15.6
22.4
9.42 (12.6)
13.19 (17.7)
18
30
6SL312
7
-
7
TE21-8AA.
6SL312
7
-1 TE23-0AA.
1.5
1.5
4
×
2.5
4
×
4
6FX
7
002-5
7
N31-
....
6FX
7
002-5
7
N41-
....
1FT7034-1AK7...
90
2.7
1.26 (1.69)
3
6SL312
7
-
7
TE13-0AA.
1
4
×
1.5
6FX
7
002-5
7
N01-
....
1FT7062-1AK7...
1FT7064-1AK7...
90
91
8.4
9
3.77 (5.06)
5.65 (7.58)
9
9
6SL312
7
-
7
TE21-0AA.
6SL312
7
-
7
TE21-0AA.
1
1
4
×
1.5
4
×
1.5
6FX
7
002-5
7
N01-
....
6FX
7
002-5
7
N01-
....
Cooling:
Internal air cooling
External air cooling
0
1
Power cable:
MOTION-CONNECT 800PLUS
MOTION-CONNECT 500
8
5
Motor Module:
Single Motor Module
Double Motor Module
1
2
Without brake cores
With brake cores
C
D
Length code
....
For information on the cables refer to
MOTION-CONNECT connection systems
1)
These values refer to
n
= 4000 rpm.
2)
These values refer to
n
= 5500 rpm.
3)
These values refer to
n
= 4500 rpm.
4)
Optimum efficiency in continuous duty.
5)
With default setting of the pulse frequency.
6)
The current carrying capacity of the power cables complies with EN 60204-1 for installation type C, for continuous duty at an ambient air temperature of
40 °C (104 °F).
7)
P
[kW] =
9550
calc
M
[Nm]
×
n
rated
0
5250
calc
M
[lb
f
-ft]
×
n
0
rated
P
[hp] =
© Siemens AG 2016