SIEMENS
5/120
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Supplementary system components
DME20 DRIVE-CLiQ Hub Module
■
Technical specifications
■
Selection and ordering data
■
Integration
Signals from more than one encoder can be collected with
one DRIVE-CLiQ Hub Module and forwarded to the Control Unit
through a single DRIVE-CLiQ cable.
With the DRIVE-CLiQ Hub Module, individual DRIVE-CLiQ
devices can be removed without interrupting the data exchange
with the remaining devices in the DRIVE-CLiQ line.
Article No.
6SL3055-0AA00-6AB0
Product designation
DME20 DRIVE-CLiQ Hub Module
Power requirement at 24 V DC,
max.
without DRIVE-CLiQ supply
0.15 A
• Conductor cross-section, max.
4 × 0.75 mm
2
Degree of protection
IP67
Width
99 mm (3.9 in)
Height
149 mm (5.87 in)
Depth
55.7 mm (2.19 in)
without connector
Net weight
0.8 kg (1.76 lb)
Certificate of suitability
cULus
Description
Article No.
DME20 DRIVE-CLiQ Hub Module
Without DRIVE-CLiQ cable; without
electronics power supply cable
and circular connector for 24 V DC
6SL3055-0AA00-6AB0
Accessories
24 V DC power supply cable
Ordering and delivery
Phoenix Contact
www.phoenixcontact.com
• Shielded connector, 5-pole, can
be assembled by the user
Art. No. 1508365
• Unshielded connector, 4-pole,
can be assembled by the user,
Speedcon quick-release lock
Art. No. 1521601
Accessories for re-ordering
SINAMICS/SINUMERIK/
SIMOTION
dust-proof
blanking plugs
For DRIVE-CLiQ port
• 6 units
6SL3066-4CA01-0AA0
• 50 units
6SL3066-4CA00-0AA0
G_D211_EN_00067c
DMC20
or
DME20
DRIVE-CLiQ
Hub Module
Control
Units
Sensor
Module
Sensor
Module
Sensor
Module
X103
X102
X101
X505
X504
X503
X502
X501
X500
X500
X100
DRIVE-CLiQ
X500
X500
DMC20
or
DME20
DRIVE-CLiQ
Hub Module
CU320-2
D4x5-2
CX32-2
Control
Units
G_D211_EN_00068b
Drive 1
Single
Motor
Module
Drive 2
Single
Motor
Module
Drive 5
Single
Motor
Module
X103
X102
X101
X505
X504
X503
X502
X501
X500
X100
DRIVE-CLiQ
X200
X201
X202
X200
X201
X202
...
...
...
...
X200
X201
X202
© Siemens AG 2016