SIEMENS
5/99
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Blocksize format – Power Modules
Line filter
■
Overview
In plants with strict EMC requirements, the line filter for frame
size FSA restricts the conducted interference emanating from
the PM340 Power Module to the limit values of Class C2 as
defined in EN 61800-3. The line filter is only suitable for direct
connection to TN line supplies.
Note:
The line filter is designed only for PM340 Power Modules of
frame size FSA and a line voltage of 380 V to 480 V 3 AC.
All other PM340 Power Modules are available with integrated
line filter.
■
Integration
Line filter, line reactor and Power Module can be mounted in front
of one another.
■
Technical specifications
■
Selection and ordering data
Power supply
G_D211_EN_00079a
Line
reactor
Power
Module
Line
filter
Line voltage
380 … 480 V 3 AC
Line filter
6SE6400-2FA00-6AD0
Rated current
6 A
Power loss
<5 W
Line connection
L1, L2, L3
Screw-type terminals
• Conductor cross-section
1 ... 2.5 mm
2
PE connection
M4 screw stud
Load connection
U, V, W, PE
Shielded cable
• Conductor cross-section
4 × 1.5 mm
2
• Length, approx.
0.24 m (0.79 ft)
Degree of protection
IP20 (with correctly connected
load connection cable)
Dimensions
• Width
73.5 mm (2.89 in)
• Height
200 mm (7.87 in)
• Depth
44 mm (1.73 in)
Net weight
0.5 kg (1 lb)
Certificate of suitability
cURus
Suitable for
Power Module in
blocksize format
Type (rated output current)
6SL3210-1SE11-...
(1.3 A and 1.7 A)
6SL3210-1SE12-... (2.2 A)
6SL3210-1SE13-... (3.1 A)
6SL3210-1SE14-... (4.1 A)
Suitable for
Power Module in
blocksize format
Frame size FSA
Line filter
Type
Article No.
Line voltage 380 ... 480 V 3 AC
6SL3210-1SE11-...
6SL3210-1SE12-...
6SL3210-1SE13-...
6SL3210-1SE14-...
6SE6400-2FA00-6AD0
© Siemens AG 2016