SIEMENS
5/79
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Chassis format – Motor Modules
Single Motor Modules
DC link voltage
510 … 720 V DC
Single Motor Module in chassis format
6SL3320-...
1TE32-1AA3
1TE32-6AA3
1TE33-1AA3
1TE33-8AA3
1TE35-0AA3
Output current
• Rated current
I
rated
A
210
260
310
380
490
• Base-load current
I
L
A
205
250
302
370
477
• Base-load current
I
H
A
178
233
277
340
438
• For S6 duty
I
S6
(40 %)
A
230
285
340
430
540
•
I
max
A
307
375
453
555
715
Type rating
1)
• Based on
I
rated
kW (HP)
110 (150)
132 (200)
160 (250)
200 (300)
250 (400)
• Based on
I
H
kW (HP)
90 (125)
110 (150)
132 (200)
160 (250)
200 (350)
Rated pulse frequency
kHz
2
2
2
2
2
Rated DC link current
I
d
2)
When supplied via
• Active Line Module
A
227
281
335
411
529
DC link capacitance
µ
F
4200
5200
6300
7800
9600
Power requirement
• At 24 V DC, max.
A
0.8
0.8
0.9
0.9
0.9
• Fan supply with 400 V 2 AC,
50/60 Hz, max.
A
0.63/0.95
1.13/1.7
1.8/2.7
1.8/2.7
1.8/2.7
Power loss, max.
kW
1.94
2.6
3.1
3.8
4.5
Cooling air requirement
m
3
/s (ft
3
/s)
0.17 (6)
0.23 (8.1)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
64/67
64/67
69/73
69/73
69/73
DC link connection
DCP, DCN
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
• Conductor cross-section, max.
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
Motor connection
U2, V2, W2
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
• Conductor cross-section, max.
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
PE connection
M10 screw
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross-section, max.
mm
2
2 × 185
2 × 185
2 × 240
2 × 240
2 × 240
Motor brake connection
–
–
–
–
–
Motor cable length, max.
Without external options
• Shielded
m (ft)
300 (984)
300 (984)
300 (984)
300 (984)
300 (984)
• Unshielded
m (ft)
450 (1476)
450 (1476)
450 (1476)
450 (1476)
450 (1476)
Degree of protection
IP20
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
326 (12.83)
326 (12.83)
326 (12.83)
326 (12.83)
326 (12.83)
• Height
mm (in)
1400 (55.12)
1400 (55.12)
1533 (60.35)
1533 (60.35)
1533 (60.35)
• Depth
mm (in)
356 (14.02)
356 (14.02)
545 (21.46)
545 (21.46)
545 (21.46)
Frame size
FX
FX
GX
GX
GX
Net weight
kg (lb)
95 (210)
95 (210)
136 (300)
136 (300)
136 (300)
1)
Rated power of a typical standard asynchronous motor at 600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
■
Technical specifications
(continued)