SINAMICS S120 drive system
Chassis format – Motor Modules
Single Motor Modules
■
Overview
The Single Motor Modules in chassis format feature the following
interfaces as standard:
•
1 DC link connection (DCP, DCN) for connecting to the
supply DC busbar
•
1 DC link connection (DCPA, DCNA) for connecting a
Braking Module
•
1 electronics power supply connection
•
3 DRIVE-CLiQ sockets
•
1 motor connection
•
1 safe standstill input (enable pulses)
•
1 temperature sensor input (KTY84-130/PT1000/PT100
two-wire or PTC)
•
1 PE connection
The status of the Motor Modules is indicated via two multi-color
LEDs.
The scope of supply of the Motor Modules includes:
•
Frame sizes FX and GX:
- 0.60 m (1.97 ft) DRIVE-CLiQ cable for connection to the
adjacent Motor Module
■
Integration
The Single Motor Module receives its control information via
DRIVE-CLiQ from:
•
CU320-2 Control Unit
•
SINUMERIK 840D sl with
- NCU 710.3B PN
- NCU 720.3B PN
- NCU 730.3B PN
- Numeric Control Extensions NX10.3/NX15.3
■
Selection and ordering data
■
Technical specifications
Description
Article No.
Single Motor Module
in chassis format
Rated output current:
• 210 A
6SL3320-1TE32-1AA3
• 260 A
6SL3320-1TE32-6AA3
• 310 A
6SL3320-1TE33-1AA3
• 380 A
6SL3320-1TE33-8AA3
• 490 A
6SL3320-1TE35-0AA3
Article No.
6SL3320-...
Product designation
Single Motor Modules
in chassis format
DC link voltage
Up to 2000 m (6562 ft)
above sea level
510 … 720 V DC
(line voltage 380 … 480 V 3 AC)
Output frequency
0 … 300 Hz
1)
Electronics power supply
24 V DC -15 %/+20 %
Cooling method
Internal air cooling,
Power units with increased air
cooling by means of built-in fan
Permissible ambient and coolant
temperature (air)
During operation for line-side
components, Line Modules and
Motor Modules
0 ... 40 °C (32 ... 104 °F)
without derating,
> 40 … 55 °C (> 104 ... 131 °F)
see derating characteristics
Installation altitude
Up to 2000 m (6562 ft)
above sea level without derating,
> 2000 ... 4000 m
(6562 ... 13124 ft)
above sea level
see derating characteristics
Declarations of conformity
CE (Low Voltage and
EMC Directives)
Certificate of suitability
Only Motor Modules
510 ... 720 V DC
cULus
Safety Integrated
Safety Integrity Level 2 (SIL 2)
acc. to IEC 61508,
Performance Level d (PLd)
acc. to ISO 13849-1 and
Control Category 3 acc. to
ISO 13849-1 or EN 954-1
1)
Note correlation between max. output frequency, pulse frequency, and
current derating (250
µ
s current controller cycle; 4 kHz pulse frequency,
see characteristics for derating).
© Siemens AG 2016