SIEMENS
5/76
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Chassis format – Line Modules
Active Line Modules
> Active Interface Modules
■
Overview
Active Interface Modules are used in combination with Active
Line Modules in chassis format. Active Interface Modules
contain a Clean Power Filter with basic RI suppression, the
pre-charging circuit for the Active Line Module, the line voltage
sensing circuit and monitoring sensors. The bypass contactor
is an integral component in types FI and GI, ensuring a highly
compact design.
Line harmonics are largely suppressed by the Clean Power Filter.
■
Overview
(continued)
The scope of supply of the Active Interface Modules includes:
•
Frame size FI:
- 0.60 m (1.97 ft) DRIVE-CLiQ cable for connection between
Active Interface Module and Active Line Module
- 1.45 m (4.76 ft) DRIVE-CLiQ cable for connection between
the Control Unit or the SINUMERIK NCU and first Motor
Module
•
Frame size GI:
- 0.95 m (3.12 ft) DRIVE-CLiQ cable for connection between
Active Interface Module and Active Line Module
- 1.45 m (4.76 ft) DRIVE-CLiQ cable for connection between
the Control Unit or the SINUMERIK NCU and first Motor
Module
■
Selection and ordering data
■
Technical specifications
Line voltage 380 … 480 V 3 AC
Rated power of
the Active Line
Module
Suitable for
Active Line Module
in chassis format
Active Interface Module
kW (HP)
Article No.
132 (200)
160 (225)
6SL3330-7TE32-1AA3
6SL3330-7TE32-6AA3
6SL3300-7TE32-6AA0
235 (350)
6SL3330-7TE33-8AA3
6SL3300-7TE33-8AA0
300 (450)
6SL3330-7TE35-0AA3
6SL3300-7TE35-0AA0
Line voltage
380 … 480 V 3 AC
Active Interface Module in chassis format
6SL3300-7TE32-6AA0
6SL3300-7TE33-8AA0
6SL3300-7TE35-0AA0
Rated current
A
210
260
380
490
Bypass contactor
Included
Included
Included
Included
DC link capacitance
of the drive line-up, max.
µ
F
41600
41600
76800
76800
Power requirement
• 24 V DC electronics power supply, max.
A
0.17
0.17
0.17
0.17
• Fan supply with 230 V 2 AC, 50/60 Hz, max.
A
0.45/0.6
0.45/0.6
0.9/1.2
0.9/1.2
Power loss, max.
kW
2.1
2.2
3.0
3.9
Cooling air requirement
m
3
/s (ft
3
/s)
0.24 (8.5)
0.24 (8.5)
0.47 (16.6)
0.47 (16.6)
Sound pressure level
L
pA
(1 m) at 50/60 Hz
dB
71/73
71/73
71/73
71/73
Line/load connection
L1, L2, L3 / U2, V2, W2
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
Flat connector for
M10 screw
• Conductor cross-section, max.
mm
2
2 × 185
2 × 185
2 × 185
2 × 185
PE connection
M10 screw
M10 screw
M10 screw
M10 screw
• Conductor cross-section, max.
mm
2
2 × 185
2 × 185
2 × 185
2 × 185
Degree of protection
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
325 (12.80)
325 (12.80)
325 (12.80)
325 (12.80)
• Height
mm (in)
1400 (55.12)
1400 (55.12)
1533 (60.35)
1533 (60.35)
• Depth
mm (in)
355 (13.98)
355 (13.98)
544 (21.42)
544 (21.42)
Frame size
FI
FI
GI
GI
Net weight
kg (lb)
135 (298)
135 (298)
190 (419)
190 (419)
Certificate of suitability
cURus
cURus
cURus
cURus
Suitable for Active Line Module
in chassis format
Type
6SL3330-7TE32-1AA3
6SL3330-7TE32-6AA3
6SL3330-7TE33-8AA3
6SL3330-7TE35-0AA3
• Rated power of the Active Line Module
kW
132 (200)
160 (225)
235 (350)
300 (450)
© Siemens AG 2016