SIEMENS
5/63
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Booksize format – Motor Modules
Double Motor Modules
■
Technical specifications
(continued)
Article No.
6SL3120-2TE13-0AA4
6SL3120-2TE15-0AA4
6SL3120-2TE21-0AA4
6SL3120-2TE21-8AA3
Product designation
Double Motor Module in booksize format with internal
air cooling
Article No.
6SL3121-2TE13-0AA4
6SL3121-2TE15-0AA4
6SL3121-2TE21-0AA4
6SL3121-2TE21-8AA3
Product designation
Double Motor Module in booksize format with external
air cooling
DC link voltage 510 … 720 V DC
Output current
Rated current
I
rated
A
2 × 3
2 × 5
2 × 9
2 × 18
For S6 duty
I
S6
(40 %)
A
2 × 3.5
2 × 6
2 × 10
2 × 24
Base-load current
I
H
A
2 × 2.6
2 × 4.3
2 × 7.7
2 × 15.3
I
max
A
2 × 9
2 × 15
2 × 27
2 × 36
Type rating
1)
Based on
I
rated
kW (HP)
2 × 1.6 (1.5)
2 × 2.7 (3)
2 × 4.8 (5)
2 × 9.7 (10)
Based on
I
H
kW (HP)
2 × 1.4 (1)
2 × 2.3 (2.5)
2 × 4.1 (5)
2 × 8.2 (10)
DC link current
I
d
2)
A
7.2
12
22
43
Current carrying capacity
DC link busbars
A
100
100
100
100
24 V DC busbars
3)
A
20
20
20
20
DC link capacitance
µ
F
220 With internal cooling
220
220
705
Power requirement at
24 V DC, max.
A
1.15
1.15
1.15
1.0
Internal/external air cooling
• Power loss
4)
-
Maximum losses with
internal air cooling
in control cabinet
kW
0.10
0.13
0.19
0.35
-
Typical losses with
internal air cooling
in control cabinet
5)
0.05
0.08
0.15
0.28
-
With external air cooling,
int./ext.
4)
kW
0.06/0.035
0.07/0.06
0.09/0.095
0.105/0.24
• Cooling air requirement
m
3
/s
(ft
3
/s)
0.008 (0.3)
0.008 (0.3)
0.008 (0.3)
0.016 (0.6)
• Sound pressure level
L
pA
(1 m)
dB
< 60
< 60
< 60
< 60
Motor connection
U2, V2, W2
2 connectors (X1, X2),
max. 30 A (not included in scope of supply,
see Accessories
)
Shield connection
Integrated in
connector (X1, X2)
Integrated in
connector (X1, X2)
Integrated in
connector (X1, X2)
Integrated in
connector (X1, X2)
PE connection
M5 screw
M5 screw
M5 screw
M5 screw
Motor brake connection
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A
Motor cable length, max.
• Shielded
m (ft)
50 (164)
50 (164)
50 (164)
70 (230)
• Unshielded
m (ft)
75 (246)
75 (246)
75 (246)
100 (328)
Degree of protection
IP20
IP20
IP20
IP20
Width
mm (in)
50 (1.97)
50 (1.97)
50 (1.97)
100 (3.94)
Height
mm (in)
380 (14.96)
380 (14.96)
380 (14.96)
380 (14.96)
Depth
• With internal air cooling
mm (in)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
• With external air cooling
on/behind mounting surface
mm (in)
226/66.5 (8.90/2.62)
226/66.5 (8.90/2.62)
226/66.5 (8.90/2.62)
226/66.5 (8.90/2.62)
Net weight
• With internal air cooling
kg (lb)
5.3 (11.7)
5.3 (11.7)
5.5 (12.1)
6.8 (15)
• With external air cooling
kg (lb)
5.8 (12.8)
5.8 (12.8)
5.7 (12.6)
8.6 (19)
1)
Rated power of a typical standard asynchronous motor at 600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
3)
If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A,
an additional 24 V DC connection using a 24 V terminal adapter is required (max. cross-section 6 mm
2
, max. fuse protection 20 A).
4)
Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.
5)
With max. motor cable length 30 m (98 ft), pulse frequency 4 kHz and DC link voltage 540 … 600 V.
© Siemens AG 2016