5/56
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Booksize format – Motor Modules
Single Motor Modules
■
Technical specifications
(continued)
Article No.
6SL3120-1TE13-0AA4
6SL3120-1TE15-0AA4
6SL3120-1TE21-0AA4
6SL3120-1TE21-8AA4
6SL3120-1TE23-0AA4
Product designation
Single Motor Module in booksize format with internal
air cooling
Article No.
6SL3121-1TE13-0AA4
6SL3121-1TE15-0AA4
6SL3121-1TE21-0AA4
6SL3121-1TE21-8AA4
6SL3121-1TE23-0AA3
Product designation
Single Motor Module in booksize format with external
air cooling
DC link voltage 510 … 720 V DC
Output current
• Rated current
I
rated
A
3
5
9
18
30
• Base-load current
I
H
A
2.6
4.3
7.7
15.3
25.5
• For S6 duty
I
S6
(40 %)
A
3.5
6
10
24
40
•
I
max
A
9
15
27
54
56
Type rating
1)
• Based on
I
rated
kW (HP)
1.6 (1.5)
2.7 (3)
4.8 (5)
9.7 (10)
16.0 (20)
• Based on
I
H
kW (HP)
1.4 (1)
2.3 (2.5)
4.1 (5)
8.2 (10)
13.7 (18)
Rated pulse frequency
kHz
4
4
4
4
4
DC link current
I
d
2)
A
3.6
6
11
22
36
Current carrying
capacity
• DC link busbars
3)
A
100
100
100
100
100
• 24 V DC busbars
4)
A
20
20
20
20
20
DC link capacitance
µ
F
110
110
110
220
710
Power requirement at
24 V DC, max.
A
0.85
0.85
0.85
0.85
0.9
Internal/external air
cooling
• Power loss
5)
-
Maximum losses
with internal air
cooling in control
cabinet
W
50
70
100
190
310
-
Typical losses
with internal air
cooling in control
cabinet
6)
W
30
40
60
140
260
-
With external air
cooling, int./ext.
W
35/15
40/30
55/45
100/90
100/210
• Cooling air
requirement
m
3
/s
(ft
3
/s)
0.008 (0.3)
0.008 (0.3)
0.008 (0.3)
0.008 (0.3)
0.016 (0.6)
• Sound pressure level
L
pA
(1 m)
dB
< 60
< 60
< 60
< 60
< 60
Motor connection
7)
U2, V2, W2
Connector (X1),
max. 30 A
Connector (X1),
max. 30 A
Connector (X1),
max. 30 A
Connector (X1),
max. 30 A
Connector (X1),
max. 30 A
Shield connection
Integrated in
connector (X1)
Integrated in
connector (X1)
Integrated in
connector (X1)
Integrated in
connector (X1)
Integrated in
connector (X1)
PE connection
M5 screw
M5 screw
M5 screw
M5 screw
M5 screw
Motor brake
connection
Integrated into the
plug-in motor
connector (X1)
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1)
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1)
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1)
24 V DC, 2 A
Integrated into the
plug-in motor
connector (X1)
24 V DC, 2 A
1)
Rated power of a typical standard asynchronous motor at 600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
3)
With reinforced DC link busbar set, 150 A is possible (accessories).
4)
If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A, an additional 24 V DC
connection using a 24 V terminal adapter is required (max. cross-section 6 mm
2
, max. fuse protection 20 A).
5)
Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.
6)
With max. motor cable length 30 m (98 ft), pulse frequency 4 kHz and DC link voltage 540 … 600 V.
7)
Connector not included in scope of supply,
see Accessories
.
© Siemens AG 2016