SIEMENS
5/37
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Booksize format – Line Modules
Active Line Modules
■
Technical specifications
(continued)
1 2 3
1)
Higher peak power is possible in combination with the Active Interface Module 6SL3100-0BE25-5AB0
(for operating cycle constraints,
see SINAMICSS120 Manual
).
2)
Power loss of Active Line Module at rated power including losses of 24 V DC electronics power supply.
3)
Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and
are to be dimensioned accordingly.
Article No.
6SL3130-7TE21-6AA4
6SL3130-7TE23-6AA3
6SL3130-7TE25-5AA3
6SL3130-7TE28-0AA3
6SL3130-7TE31-2AA3
Product designation
Active Line Module in booksize format with internal
air cooling
Article No.
6SL3131-7TE21-6AA3
6SL3131-7TE23-6AA3
6SL3131-7TE25-5AA3
6SL3131-7TE28-0AA3
6SL3131-7TE31-2AA3
Product designation
Active Line Module in booksize format with external
air cooling
Line voltage 380 … 480 V 3 AC
Infeed/regenerative
feedback power
• Rated power
P
rated
-
at 380 V 3 AC
kW
16
36
55
80
120
-
at 460 V 3 AC
3)
(HP)
(18)
(40)
(60)
(100)
(150)
• For S6 duty
P
S6
(40 %)
kW
21
47
71
106
145
•
P
max
kW
35
70
91
131
175
DC link current
• At 600 V DC
A
27
60
92
134
200
• For S6 duty (40 %)
A
35
79
121
176
244
• Maximum
A
59
117
152 (176
1)
)
218
292
Input current
• Rated current
At 380 V/400 V/480 V
3 AC
A
26/25/21
58/55/46
88/84/70
128/122/102
192/182/152
• For S6 duty (40 %)
at 400 V
A
32
71
108
161
220
• At 400 V max.
A
54
107
139 (168
1)
)
200
267
Power requirement,
max.
24 V DC electronics
power supply
A
1.1
1.5
1.9
2.0
2.5
Current carrying
capacity
• 24 V DC busbars
A
20
20
20
20
20
• DC link busbars
A
100
200
200
200
200
DC link capacitance
• Active Line Module
µ
F
710
1410
1880
2820
3995
• Drive line-up, max.
µ
F
20000
20000
20000
20000
20000
Internal/external
air cooling
• Power loss
1)
-
Total power loss for
cooling methods:
Internal air cooling,
external air cooling
kW
0.29
0.67
0.95
1.39
2.26
-
With external air
cooling int.
2)
/ext.
kW
0.09/0.2
0.17/0.5
0.25/0.7
0.3/1.0
0.55/1.71
• Cooling air require-
ment
m
3
/s
(ft
3
/s)
0.016 (0.6)
0.031 (1.1)
0.044 (1.6)
0.144 (5.1)
0.144 (5.1)
• Sound pressure level
L
pA
(1 m)
dB
< 60
< 65
< 60
< 75
< 75
© Siemens AG 2016