SIEMENS
5/36
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Booksize format – Line Modules
Active Line Modules
■
Technical specifications
Article No.
6SL313 . -7TE...
Product designation
Active Line Modules
in booksize format
Line voltage 3 AC
Up to 2000 m (6562 ft)
above sea level
380 … 480 V ±10 %
-15 % < 1 min
SCCR
(
S
hort
C
ircuit
C
urrent
R
ating)
65 kA in conjunction with the
recommended fuses class
J
or
circuit breakers in accordance
with UL489/CSA 22.2 No. 5-02
see recommended line-side
components
Line frequency
47 … 63 Hz
Line power factor
• Active mode
-
Fundamental (cos
ϕ
1
)
1.0 (factory setting)
can be altered by inputting a
reactive current setpoint
-
Total (
λ
)
1.0 (factory setting)
• Smart Mode
-
Fundamental (cos
ϕ
1
)
> 0.96
- Total
0.65 … 0.90
Efficiency
98 %
Overvoltage category
acc. to EN 60664-1
Class III
DC link voltage
V
d
In
Active Mode
, the DC link voltage
is regulated and can be adjusted
as a voltage decoupled from the
line voltage.
In
Smart Mode
the
DC link voltage is regulated in
proportion to the line voltage to the
mean rectified line voltage value.
Factory setting for DC link voltage:
380 ... 400 V 3 AC: 600 V
(Active Mode)
400 ... 415 V 3 AC: 625 V
(Active Mode)
416 ... 480 V 3 AC:
1.35 × line voltage (Smart Mode)
1)
Electronics power supply DC
24 V -15 %/+20 %
Radio interference suppression
• Standard
Active Line Module +
Active Interface Module
Category C3 to EN 61800-3
up to 350 m (1148 ft)
total cable length
• With line filter
Category C2 to EN 61800-3
up to 350 m (1148 ft)
total cable length
Category C3 to EN 618003
up to 350 ... 1000 m
(1148 ... 3281 ft)
total cable length
Cooling method
Internal air cooling
Power units with increased air
cooling by means of built-in fan
External air cooling
Power units with increased air
cooling by means of built-in fan
Ambient or
coolant temperature (air)
During operation for line-side
components, Line Modules and
Motor Modules
0 ... 40 °C (32 ... 104 °F)
without derating,
> 40 ... 55 °C (> 104 ... 131 °F)
with derating
Installation altitude
Up to 1000 m (3281 ft)
above sea level without derating
> 1000 ... 4000 m
(3281 ... 13124 ft)
above sea level with derating
Certificate of suitability
CE, cULus
Article No.
6SL313 . -7TE...
Product designation
Active Line Modules
in booksize format
1)
Active Mode can also be selected if the connected motors are suitable for
> 650 V DC.
© Siemens AG 2016