SIEMENS
5/29
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Booksize format – Line Modules
Smart Line Modules
■
Technical specifications
(continued)
1
2
3
1)
Power loss of Smart Line Module at rated power including losses of 24 V DC electronics power supply.
2)
Power loss of the power electronics + power loss of the 24 V electronics.
3)
Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and
are to be dimensioned accordingly.
Article No.
6SL3130-6AE15-0AB1
6SL3130-6AE21-0AB1
6SL3130-6TE21-6AA4
6SL3130-6TE23-6AA3
6SL3130-6TE25-5AA3
Product designation
Smart Line Module in booksize format with internal
air cooling
Article No.
6SL3131-6AE15-0AA1
6SL3131-6AE21-0AA1
6SL3131-6TE21-6AA3
6SL3131-6TE23-6AA3
6SL3131-6TE25-5AA3
Product designation
Smart Line Module in booksize format with external
air cooling
Line voltage 380 ... 480 V 3 AC
Infeed/regenerative
feedback power
• Rated power
P
rated
-
at 380 V 3 AC
kW
5
10
16
36
55
-
at 460 V 3 AC
3)
(HP)
(5)
(10)
(18)
(40)
(60)
• For S6 duty
P
S6
(40 %)
kW
6.5
13
21
47
71
•
P
max
kW
10
20
35
70
91
DC link current
• At 540 V/600 V DC
A
9.3/8.3
18.5/16.6
30/27
67/60
105/92
• For S6 duty (40 %)
A
11
22
35
79
138
• Maximum
A
16.6
33.2
59
117
178
Input current
• Rated current
At 380 V/400 V/480 V
3 AC
A
8.6/8.1/6.7
17/16.2/12.8
26/25/21
58/55/46
94/90/77
• For S6 duty (40 %)
at 400 V
A
10.6
21.1
33
72
106
• At 400 V max.
A
15.7
31.2
54
107
130
Power requirement,
max.
24 V DC electronics
power supply
A
0.8
0.9
0.95
1.5
1.9
Current carrying
capacity
• 24 V DC busbars
A
20
20
20
20
20
• DC link busbars
A
100
100
100
200
200
DC link
capacitance
• Smart Line Module
µ
F
220
330
710
1410
1880
• Drive line-up, max.
µ
F
6000
6000
20000
20000
20000
Internal/external
air cooling
• Power loss
1)
-
Internal air cooling
kW
0.08
0.14
0.19
0.405
0.665
-
External air cooling
int.
2)
/ext./total
kW
0.04/0.04/0.08
0.065/0.075/0.14
0.065/0.125/0.19
0.115/0.29/0.405
0.185/0.48/0.665
• Cooling air requirement
m
3
/s
(ft
3
/s)
0.008 (0.3)
0.008 (0.3)
0.016 (0.6)
0.031 (1.1)
0.044 (1.6)
• Sound pressure level
L
pA
(1 m)
dB
< 60
< 60
< 60
< 60
< 60
Line connection
U1, V1, W1
Screw-type terminals
(X1)
Screw-type terminals
(X1)
Screw-type terminals
(X1)
M6 screw studs (X1)
M6 screw studs (X1)
• Conductor cross-section
mm
2
2.5 … 6
2.5 … 6
2.5 … 10
2.5 … 50
2.5 … 95
Shield connection
Shield connection
plate integrated into
the connector
Shield connection
plate integrated into
the connector
Shield connection
plate integrated into
the connector
See Accessories
See Accessories
PE connection
M5 screw
M5 screw
M5 screw
M6 screw
M6 screw
Cable length, max.
Total of all motor cables
and DC link
• Shielded
m (ft)
350 (1148)
350 (1148)
630 (2067)
630 (2067)
1000 (3281)
• Unshielded
m (ft)
560 (1837)
560 (1837)
850 (2789)
850 (2789)
1500 (4921)
Degree of protection
IP20
IP20
IP20
IP20
IP20
© Siemens AG 2016