SINAMICS S120 drive system
Booksize format – Line Modules
Smart Line Modules
■
Overview
1
Smart Line Module
Smart Line Modules are stall-protected, line-commutated infeed/
regenerative feedback units (diode bridge for incoming supply;
stall-protected, line-commutated regenerative feedback via
IGBTs) with 100 % continuous regenerative feedback power. The
regenerative feedback capability of the modules can be deacti-
vated by means of a digital input (Smart Line Modules 5 kW and
10 kW) or by parameterization (Smart Line Modules 16 kW,
36 kW and 55 kW).
Smart Line Modules are designed for connection to grounded
TN and TT supply systems and to non-grounded IT supply
systems.
The DC link is pre-charged by means of integrated pre-charging
resistors.
The associated line reactor is absolutely essential for operating
a Smart Line Module.
■
Design
The Smart Line Modules in booksize format feature the following
connections and interfaces as standard:
•
1 power connection via screw-type terminals
•
1 connection for the 24 V DC electronic power supply via the
24 V terminal adapter included in the scope of supply
•
1 DC link connection via integrated DC link busbars
•
2 PE connections
•
2 digital inputs
(only with 5 kW and 10 kW Smart Line Modules)
•
1 digital output
(only with 5 kW and 10 kW Smart Line Modules)
•
3 DRIVE-CLiQ sockets
(only with 16 kW, 36 kW and 55 kW Smart Line Modules)
The status of the Smart Line Modules is indicated via two multi-
color LEDs.
The signal cable shield can be connected to the Line Module by
means of a shield connection terminal, e.g. type KLBÜ 3-8 SC
by Weidmüller.
■
Design
(continued)
The scope of supply of the Smart Line Modules includes:
•
DRIVE-CLiQ cable for connection to the adjacent Control Unit
on the left for drive control, length 0.11 m (4.33 in)
(on 16 kW, 36 kW and 55 kW Smart Line Modules only)
•
2 blanking plugs for sealing unused DRIVE-CLiQ sockets
(on 16 kW, 36 kW and 55 kW Smart Line Modules only)
•
DRIVE-CLiQ cable (length depends on module width) to
connect Smart Line Module to adjacent Motor Module,
length = width of Smart Line Module + 0.11 m (4.33 in)
•
Jumper for connecting the 24 V DC busbar to the adjacent
Motor Module
•
24 V terminal adapter (X24)
•
Connector X21 for digital inputs and outputs
•
Connector X22 for digital inputs and outputs
(only with 5 kW and 10 kW Smart Line Modules)
•
Connector X1 for the line connection
(only with 5 kW and 10 kW Smart Line Modules)
•
1 set of warning labels in 30 languages
■
Technical specifications
1)
The DC link voltage is regulated to the mean value of the rectified
line voltage.
Article No.
6SL313.-6
....
-
....
Product designation
Smart Line Modules
in booksize format
Line voltage 3 AC
Up to 2000 m (6562 ft) above
sea level
380 … 480 V ±10 %
-15 % < 1 min
Line frequency
47 … 63 Hz
SCCR
(
S
hort
C
ircuit
C
urrent
R
ating)
65 kA in conjunction with the
recommended fuses class
J
or
circuit breakers in accordance
with UL489/CSA 22.2 No. 5-02
see recommended line-side
components
Line power factor
At rated power
• Fundamental (cos
ϕ
1
)
> 0.96
• Total (
λ
)
0.65 … 0.90
Overvoltage category
acc. to EN 60664-1
Class III
DC link voltage, approx.
1.35 × line voltage
1)
Electronics power supply DC
24 V -15 %/+20 %
Radio interference suppression
• Standard
No radio interference suppression
• With line filter
Category C2 to EN 61800-3
up to overall cable length 350 m
(1148 ft) (shielded)
Cooling method
Internal air cooling
External air cooling
Power units with increased air
cooling by means of built-in fan
Ambient or
coolant temperature (air)
During operation for line-side
components, Line Modules and
Motor Modules
0 ... 40 °C (32 ... 104 °F)
without derating,
> 40 ... 55 °C (> 104 ... 131 °F)
with derating
Installation altitude
Up to 1000 m (3281 ft) above
sea level without derating
> 1000 ... 4000 m
(3281 ... 13124 ft) above
sea level with derating
Certificate of suitability
CE, cULus
© Siemens AG 2016