SIEMENS
4/17
Siemens NC 62 · 2016
4
SINUMERIK Integrate
Integrate for engineering
SinuCom
■
Overview
The SinuCom program package consists of:
•
SinuCom NC
- SinuCom NC Trace
- SinuCom NC SI
•
SinuCom FFS
•
SinuCom ARC
•
Commissioning software for SINAMICS S120
The SinuCom program package supports simple and effective
commissioning of control systems. The programs provide com-
prehensive support to commissioning and service personnel of
machine manufacturers for the following:
•
Commissioning of the machine including utilization of the
trace functionality, for the Safety Integrated acceptance test
•
Creation of CF card images
•
Administration of data for series start-up
•
Transmission of CNC user data
•
Know-how protection – guard technological knowledge
against unauthorized access
■
Function
SinuCom NC
The SinuCom NC program facilitates commissioning of control
systems by providing:
•
Dialog-based parameterization of machine data
•
Administration of data for series start-up
•
Integrated online help for functions, machine data and alarms
•
Functional description in German and English as PDF (part of
the online help)
SinuCom NC Trace
The SinuCom NC Trace function permits the dynamic recording
of CNC, PLC and HMI variables, and of drive signals that are
available via the CNC. These variables can be displayed,
printed out or stored in a file, similar to using an oscillograph or
logic analyzer. The SinuCom NC Trace function helps with:
•
Fault detection and fault correction
•
Machine performance analysis, benchmarking and tuning
•
Process performance analysis, benchmarking and tuning
SinuCom NC SI
The SinuCom NC SI function supports the machine manufac-
turer in automating the Safety Integrated acceptance test, and
optimizes the process:
•
Verification of machines according to the EC Machinery
Directive
•
Testing of safety functions (partly automated) during the
machine acceptance
•
Logging of measured data and test results incl. trace
functions records
•
Testing of single/special-purpose machines, machine
components (as a partial test) and series machines as
series start-up
•
Shorter start-up times since, in the new acceptance mode,
power-on alarms during the acceptance test are acknowl-
edged by RESET
•
Simple operation using prompted sequences
•
Automatic configuration of the trace functions
•
Unambiguous quality verification for original equipment
manufacturers and customers, and for dealings with
government agencies
© Siemens AG 2016