SIEMENS
4/21
Siemens NC 82 · 2017
SINAMICS S120 drive system
SINAMICS S120 in booksize format
Line Modules
> Active Line Modules
4
■
Technical specifications
(continued)
Article No.
6SL313 . -7TE...
Product brand name
SINAMICS
Product type designation
S120
Product designation
Active Line Modules
in booksize format
DC link voltage
U
d
• Active Mode
The DC link voltage is regulated
and can be adjusted as a voltage
decoupled form the line voltage.
Factory setting
380 … 400 V 3 AC: 600 V
400 … 415 V 3 AC: 625 V
• Smart Mode
The DC link voltage is regulated in
proportion to the line voltage to the
mean rectified line voltage value.
Factory setting
416 … 480 V 3 AC:
1.35 × line voltage
1)
Electronics power supply DC
24 V, -15 %/+20 %
Radio interference suppression
• Standard
Active Line Module +
Active Interface Module
Category C3 to EN 61800-3 up to
350 m total cable length
• With line filter
Category C2 to EN 61800-3
up to 350 m total cable length
Category C3 to EN 61800-3 up to
350 … 1000 m total cable length
Cooling method
Internal air cooling
External air cooling
Power units with increased air
cooling by built-in fan
Ambient or coolant temperature
(air)
During operation for line-side
components, Line Modules and
Motor Modules
0 … 40 °C without derating
> 40 … 55 °C with derating
Installation altitude
Up to 1000 m above sea level
without derating
> 1000 … 4000 m above sea level
with derating
Certificate of suitability
CE, cULus
Article No.
6SL313 . -7TE...
Product brand name
SINAMICS
Product type designation
S120
Product designation
Active Line Modules
in booksize format
Article No.
6SL3130-7TE21-6AA4
6SL3130-7TE23-6AA3
6SL3130-7TE25-5AA3
6SL3130-7TE28-0AA3
6SL3130-7TE31-2AA3
Product designation
Active Line Module in booksize format with internal
air cooling
Article No.
6SL3131-7TE21-6AA3
6SL3131-7TE23-6AA3
6SL3131-7TE25-5AA3
6SL3131-7TE28-0AA3
6SL3131-7TE31-2AA3
Product designation
Active Line Module in booksize format with external
air cooling
Product brand name
SINAMICS
Product type designation
S120
Line voltage 380 … 480 V 3 AC
Infeed/regenerative
feedback power
• Rated power
P
rated
at
380 V 3 AC
kW
16
36
55
80
120
• For S6 duty (40 %)
kW
21
47
71
106
145
•
P
max
kW
35
70
91 (110
2)
)
131
175
DC link current
• At 600 V DC
A
27
60
92
134
200
• For S6 duty (40 %)
A
35
79
121
176
244
• Maximum
A
59
117
152 (176
2)
)
218
292
Input current
• Rated current
at 380 V/400 V/
480 V 3 AC
A
26/25/21
58/55/46
88/84/70
128/122/102
192/182/152
• For S6 duty (40 %)
at 400 V
A
32
71
108
161
220
• Maximum at 400 V
A
54
107
139 (168
2)
)
200
267
Power requirement, max.
24 V DC electronics power
supply
A
1.1
1.5
1.9
2.0
2.5
Current carrying capacity
• 24 V DC busbars
A
20
20
20
20
20
• DC link busbars
A
100
200
200
200
200
1)
Active Mode can also be selected if the connected motors are suitable for > 650 V DC.
2)
Higher peak power is possible in combination with the Active Interface Module 6SL3100-0BE25-5AB0
(for operating cycle constraints, see SINAMICSS120 Manual)
.