SIEMENS
4/18
Siemens NC 82 · 2017
SINAMICS S120 drive system
SINAMICS S120 in booksize format
Line Modules
> Smart Line Modules
> Line filters
4
■
Overview
Line filter
In plants with strict EMC requirements, line filters work together
with line reactors to restrict the conducted interference emanat-
ing from the Power Modules to the limit values of Class A1 as de-
fined in EN 55011 and Category C2 as defined in EN 61800-3.
Line filters are suitable only for direct connection to TN systems.
The use of other makes of line filter can lead to malfunctions or
irreparable damage to equipment.
■
Selection and ordering data
■
Technical specifications
Suitable for
Smart Line Module
SINAMICS line filter
Rated
power
Smart
Line
Module
Booksize format
Internal air cooling
External air cooling
Rated
current
kW
Type
A
Article No.
5
6SL3130-6AE15-0AB1
6SL3131-6AE15-0AA1
12
6SL3000-0HE15-0AA0
10
6SL3130-6AE21-0AB1
6SL3131-6AE21-0AA1
25
6SL3000-0HE21-0AA0
16
6SL3130-6TE21-6AA4
6SL3131-6TE21-6AA3
36
6SL3000-0BE21-6DA0
36
6SL3130-6TE23-6AA3
6SL3131-6TE23-6AA3
74
6SL3000-0BE23-6DA1
55
6SL3130-6TE25-5AA3
6SL3131-6TE25-5AA3
105
6SL3000-0BE25-5DA0
Article No.
6SL3000-0HE15-0AA0
6SL3000-0HE21-0AA0
6SL3000-0BE21-6DA0
6SL3000-0BE23-6DA1
6SL3000-0BE25-5DA0
Product brand name
SINAMICS
SINAMICS
SINAMICS
SINAMICS
SINAMICS
Product designation
Line filter
Line filter
Line filter
Line filter
Line filter
Line voltage 380 … 480 V 3 AC
Rated current
A
12
25
36
74
105
Power loss
W
20
20
16
26
43
Line/load connection
L1, L2, L3/U, V, W
Screw-type terminals
Screw-type terminals
Screw-type terminals
Screw-type terminals
Screw-type terminals
• Conductor
cross-section
mm
2
10
10
10
35
50
PE connection
M6 screw stud
according to
DIN 46234
M6 screw stud
according to
DIN 46234
M6 screw stud
according to
DIN 46234
M6 screw stud
according to
DIN 46234
M8 screw stud
according to
DIN 46234
Degree of protection
IP20
IP20
IP20
IP20
IP20
Width
mm
60
60
50
75
100
Height
mm
285
285
429
433
466
Depth
mm
122
122
226
226
226
Net weight
kg
2.1
2.3
5.0
7.5
11.5
Certificate of suitability
cURus
cURus
cURus
cURus
cURus