SIEMENS
4/39
Siemens NC 82 · 2017
SINAMICS S120 drive system
SINAMICS S120 in booksize format
Motor Modules
> Single Motor Modules
4
■
Technical specifications
(continued)
Article No.
–
–
–
6SL3120-1TE21-8AC0
6SL3120-1TE23-0AC0
Product designation
Single Motor Module in booksize format with internal
air cooling C type
Article No.
6SL3120-1TE13-0AD0
6SL3120-1TE15-0AD0
6SL3120-1TE21-0AD0
6SL3120-1TE21-8AD0
6SL3120-1TE23-0AD0
Product designation
Single Motor Module in booksize format with internal
air cooling D type
Product brand name
SINAMICS
Product type designation
S120
DC link voltage 510 ... 720 V DC
Output current
• Rated current
I
rated
A
3
5
9
18
30
• Base-load current
I
H
A
2.6
4.3
7.7
15.3
25.5
•
I
S6
(40 %)
-
C type
A
–
–
–
24
40
-
D type
A
4
6.7
12
24
40
•
I
max
-
C type
A
–
–
–
36
56
-
D type
A
9
15
27
54
90
Type rating
1)
• Based on
I
rated
kW
1.6
2.7
4.8
9.7
16
• Based on
I
H
kW
1.4
2.3
4.1
8.2
13.7
Rated pulse frequency
kHz
4
4
4
4
4
DC link current
I
d
2)
A
3.6
6
11
22
36
Current carrying
capacity
• DC link busbars
A
100
3)
100
3)
100
3)
100
3)
100
3)
• 24 V DC busbars
4)
A
20
20
20
20
20
DC link capacitance
μF
110
110
110
220
705
Power requirement
At 24 V DC, maximum
A
0.75
0.75
0.75
0.75
0.8
Power loss
5)
typical/maximum
W
30/50
40/70
60/100
140/190
260/310
Cooling air requirement
m
3
/s
0.009
0.009
0.009
0.009
0.0155
Sound pressure level
L
pA
(1 m)
dB
<60
<60
<60
<60
<60
Motor connection
U2, V2, W2
Connector (X1)
7)
,
1.5 ... 6 mm
2
Connector (X1)
7)
,
1.5 ... 6 mm
2
Connector (X1)
7)
,
1.5 ... 6 mm
2
Connector (X1)
7)
,
1.5 ... 6 mm
2
Connector (X1)
7)
,
1.5 ... 6 mm
2
PE connection
M5 screw
M5 screw
M5 screw
M5 screw
M5 screw
Motor brake connection
Integrated into the plug-in motor connector (X1) 24 V DC, 2 A
Motor cable length,
maximum
• Shielded
m
50
50
50
70
100
• Unshielded
m
75
75
75
100
150
Degree of protection
IP20
IP20
IP20
IP20
IP20
Width
mm
50
50
50
50
100
Height
mm
380
380
380
380
380
Depth
mm
270
270
270
270
270
Net weight
kg
4.6
4.6
4.6
4.6
7.9
1)
Rated power of a typical standard asynchronous motor at 600 V DC link voltage.
2)
Rated DC link current for dimensioning an external DC connection.
3)
With reinforced DC link busbar set, 150 A is possible
(see Accessories)
.
4)
If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A, an additional 24 V DC
connection using a 24 V terminal adapter is required (max. cross-section 6 mm
2
, max. fuse protection 20 A).
5)
Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.
6)
At max. motor cable length 30 m, pulse frequency 4 kHz and DC link voltage 540 … 600 V.
7)
Connector not included in scope of supply
(see Accessories)
.
© Siemens AG 2016