SINAMICS S120 drive system
SINAMICS S120 in booksize format
Line Modules
> Basic Line Modules
> Line filters
4
■
Overview
Line filter
In plants with strict EMC requirements, line filters work together
with line reactors to restrict the conducted interference
emanating from the Power Modules to the limit values of
Class A1 as defined in EN 55011 and Category C2 as defined in
EN 61800-3. Line filters are suitable only for direct connection to
TN systems.
The use of other makes of line filter can lead to malfunctions or
irreparable damage to equipment.
■
Selection and ordering data
■
Technical specifications
Suitable for
Basic Line Module
SINAMICS line filter
Rated
power
Basic
Line
Module
Booksize format
Rated
current
kW
Type
A
Article No.
20
6SL3130-1TE22-0AA0
36
6SL3000-0BE21-6DA0
40
6SL3130-1TE24-0AA0
74
6SL3000-0BE23-6DA1
100
6SL3130-1TE31-0AA0
192
6SL3000-0BE31-2DA0
Article No.
6SL3000-0BE21-6DA0
6SL3000-0BE23-6DA1
6SL3000-0BE31-2DA0
Product brand name
SINAMICS
SINAMICS
SINAMICS
Product designation
Line filter
Line filter
Line filter
Line voltage 380 … 480 V 3 AC
Rated current
A
36
74
192
Power loss
W
16
20
90
Line/load connection
L1, L2, L3/U, V, W
Screw-type terminals
Screw-type terminals
Screw-type terminals
• Conductor cross-section
mm
2
10
35
95
PE connection
M6 screw stud
M6 screw stud
M10 screw stud
Degree of protection
IP20
IP20
IP20
Width
mm
50
75
150
Height
mm
429
433
479
Depth
mm
226
226
226
Net weight
kg
5
7.5
18.8
Certificate of suitability
cURus
cURus
cURus