SIMOTICS main motors
SIMOTICS M asynchronous and synchronous motors for SINAMICS S120
Selection guides for SIMOTICS M-1PH8 motors
> Terminal box assignment, max. connectable cable cross-sections
9
■
Options
(continued)
Terminal box type
(See selection and
ordering data for
assignment)
Cable entry
Outer
cable
diameter,
max.
1)
Number of main terminals
Cross-section
per terminal,
max.
Rated
current,
max.
2)
Power
External signals
mm (in)
mm²
A
gk803
1
×
M25
×
1.5
1
×
M16
×
1.5
3)
20 (0.79)
Phases: 3
×
M5
1
×
10
52
Grounding: 2
×
M5
gk806
1
×
M25
×
1.5
1
×
M16
×
1.5
3)
20 (0.79)
Phases: 6
×
M5
1
×
10
52
Grounding: 2
×
M5
gk813
1
×
M32
×
1.5
1
×
M16
×
1.5
3)
24.2 (0.95)
Phases: 3
×
M5
1
×
16
70
Grounding: 2
×
M5
gk823
1
×
M32
×
1.5
1
×
M16
×
1.5
3)
24.2 (0.95)
Phases: 3
×
M5
1
×
16
70
Grounding: 2
×
M5
gk826
1
×
M32
×
1.5
1
×
M16
×
1.5
3)
24.2 (0.95)
Phases: 6
×
M5
1
×
10
52
Grounding: 2
×
M5
gk833
1
×
M40
×
1.5
1
×
M16
×
1.5
3)
32 (1.26)
Phases: 3
×
M6
1
×
35
110
Grounding: 2
×
M6
gk843
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38 (1.50)
Phases: 3
×
M6
1
×
50
133
Grounding: 2
×
M6
gk846
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38 (1.50)
Phases: 6
×
M6
1
×
25
88
Grounding: 2
×
M6
gk863
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38 (1.50)
Phases: 3
×
M6
1
×
50
133
Grounding: 2
×
M6
gk873
1
×
M63
×
1.5
1
×
M16
×
1.5
3)
42.6 (1.68)
Phases: 3
×
M6
1
×
50
133
Grounding: 2
×
M6
gk874
1
×
M63
×
1.5
1
×
M16
×
1.5
3)
42.6 (1.68)
Phases: 3
×
M10
2
×
70
240
Grounding: 2
×
M6
1XB7322-P05
2
×
M50
×
1.5
1
×
M16 × 1.5
4)
38 (1.50)
Phases: 3
×
M12
2
×
50
210
Grounding: 2
×
M6
1XB7422-P06
2
×
M63
×
1.5
1
×
M16 × 1.5
4)
53 (2.09)
Phases: 3
×
M12
2
×
70
270
Grounding: 4
×
M8
1XB7700-P02
3
×
M75
×
1.5
1
×
M16 × 1.5
4)
68 (2.68)
Phases: 3
×
2
×
M12
3
×
150
700
Grounding: 3
×
fixing eyelet
1XB7712-P03
4
×
M75
×
1.5
1
×
M16 × 1.5
4)
68 (2.68)
Phases: 3
×
4
×
M16
4
×
185
1150
Grounding: 4
×
M16
For terminal box type
1XB7712-P03
, other cable entries (power) can be ordered via P options, depending on the standard:
P00
P01
P02
P04
Undrilled cable entry plate
Cable entry plate 3 × M63 × 1.5 (not with 1XB7712-P01)
Cable entry plate 3 × M75 × 1.5
Cable entry plate 4 × M63 × 1.5
For terminal box type
1XB7700-P02
,
other cable entries (power) can be ordered via P options, depending on the standard:
P00
P01
Undrilled cable entry plate
Cable entry plate 3 × M63 × 1.5
For terminal box types
1XB7322-P05
and
1XB7422-P06
, another cable entry (power) can be ordered via the P option,
depending on the standard:
P00
Undrilled cable entry plate
For options
K09
or
K10
, instead of terminal box
gk863
, terminal box
gk873
is used mounted on the side.
For options
K09
or
K10
, instead of terminal box
gk833
, terminal box
gk843
is used mounted on the side.
For options
K09
or
K10
, instead of terminal box
gk813
, terminal box
gk823
is used mounted on the side.
1)
Depending on the version of metric cable gland (based on the MOTIONCONNECT cable type and cable glands from HUGRO or from AGRO).
2)
Current-carrying capacity based on EN 60204-1/IEC 60364-5-52 with installation type E.
3)
Thread M16 × 1.5 arranged at 90° to signal connection; thread only with options A12, A25 and when 9th data position is A (without encoder).
4)
Thread M16 × 1.5 arranged opposite the signal connection (sideways to the cable entry plate); thread only with option A12 and encoder version A
(without encoder).