SIEMENS
9/76
Siemens D 21.4 · 2017
SIMOTICS main motors
SIMOTICS M asynchronous and synchronous motors for SINAMICS S120
Options for SIMOTICS M-1PH8 asynchronous and synchronous motors
9
■
Options
(continued)
Order
code
Option description
For use with motors
-Z
must be appended to the Article No. to order a motor with options.
The order code should also be specified for each additional required option
(Order codes must not be repeated in plain text in the order)
Shaft height
80 to 160
Shaft height
180 to 280
Shaft height
280
only for forced
ventilation
(11th data
position "1" or "4")
K45
Anti-condensation heating 230 V AC
–
✔
✔
K69
Pipe connection prepared NDE right
(only possible with forced ventilation, not for G00 up to G11)
–
–
✔
K70
Pipe connection prepared NDE left
(only possible with forced ventilation, not for G00 up to G11)
–
–
✔
K71
Pipe connection prepared NDE top
(only possible with forced ventilation, not for G00 up to G11)
–
–
✔
K80
Axial pipe connection NDE
(only possible for forced ventilation)
✔
Only for SH 180
and SH 225
Options
K69
,
K70
,
K71
K83
Terminal box rotated through +90 degrees
(possible in combination with option K09 or K10, or when
15th data position is "U", "V" or "W")
–
✔
1)
✔
K84
Terminal box rotated through -90 degrees
(possible in combination with option K09 or K10, or when
15th data position is "U", "V", "W" or "X")
–
✔
1)
✔
K85
Terminal box rotated through +180 degrees
(possible in combination with option K09 or K10, or when
15th data position is "U", "V", "W" or "X")
–
✔
✔
K90
Version with flange size A400
(possible if 12th data position is "2", "3" or "5")
–
Only for SH 180
–
L00
Replace terminal box (standard) with the next largest terminal box
(note dimension implications in CAD CREATOR!)
–
✔
✔
L02
Screws locked with Loctite and reinforced fan version
–
Only when
11th data
position is "1"
L03
Increased vibration stress
–
Only for SH 180
and SH 225
–
L12
Condensation drain hole
–
Standard for
water cooling
Only when
11th data
position is "1"
L27
NDE bearing in insulated version
–
Only for SH 180
Standard
L29
Enhanced corrosion protection for installation in industrial/marine climates
–
–
✔
L72
Shaft made of special steel
(Note: Option results in longer delivery times)
–
–
✔
L74
Fan version with IP65 degree of protection
2)
✔
–
–
L75
Special fan version for 400 V 3 AC with IP65 degree of protection
2)
(Note: Filter must be ordered with option Q14)
–
Only for SH 180
and SH 225
–
M03
Version for potentially explosive atmospheres Zone 2
✔
–
M39
Version for potentially explosive atmospheres Zone 22
✔
Only for SH 180
and SH 225
–
M83
Additional back-off thread on motor feet
(possible if 12th data position is "0" or "3")
–
–
✔
P00
Undrilled cable entry plate
–
✔
Not with
1XB7820-P00
P01
Cable entry plate 3 × M63 × 1.5
–
Only for
1XB7700-P02
1XB7712-P03
Only for
1XB7712-P03
P02
Cable entry plate 3 × M75 × 1.5
–
Only for
1XB7712-P03
Only for
1XB7712-P01
1XB7712-P03
P03
Cable entry plate 4 × M75 × 1.5
–
–
Only for
1XB7712-P01
P04
Cable entry plate 4 × M63 × 1.5
–
Only for
1XB7712-P03
Only for
1XB7712-P01
1XB7712-P03
–
Not possible
✔
Option available
1)
Not possible for 1PH822 and terminal box 1XB7712-P03.
2)
Regardless of the degree of protection, at high levels of atmospheric pollution, the fan must be cleaned.
© Siemens AG 2017