SIEMENS
9/75
Siemens D 21.4 · 2017
SIMOTICS main motors
SIMOTICS M asynchronous and synchronous motors for SINAMICS S120
Options for SIMOTICS M-1PH8 asynchronous and synchronous motors
9
■
Options
Order
code
Option description
For use with motors
-Z
must be appended to the Article No. to order a motor with options.
The order code should also be specified for each additional required option
(Order codes must not be repeated in plain text in the order)
Shaft height
80 to 160
Shaft height
180 to 280
Shaft height
280
only for forced
ventilation
(11th data
position "1" or "4")
A12
Additional PTC thermistor chain for alarm and tripping
(only possible for version with terminal box)
✔
✔
✔
A25
Additional temperature sensor as reserve connected to signal terminal strip
(only possible for version with terminal box)
✔
Standard
Standard
A72
2 Pt1000 temperature sensors for roller bearing temperature monitoring (DE and NDE)
–
✔
✔
B02
Factory test certificate in accordance with EN 10204 2.3 (for motor ordered)
✔
Standard
Standard
B35
Factory test certificate for vibration log
✔
✔
1)
✔
1)
B36
Factory test certificate for run-out log
✔
Only for SH 180
and SH 225
–
G00
External fan NDE left, air inlet at NDE
(possible if 15th data position is U, W or X)
–
–
✔
G02
External fan NDE right, air inlet at NDE
(possible if 15th data position is V, W or X)
–
–
✔
G06
External fan DE left, air inlet at NDE
(possible if 11th digit = 1 and 15th digit = U, V, or W;
possible if 11th digit = 4 and 15th digit = W)
–
–
✔
G07
External fan DE left, air inlet at DE
(possible if 11th digit = 1 and 15th digit = U, V, or W;
possible if 11th digit = 4 and 15th digit = W)
–
–
✔
G08
External fan DE right, air inlet at NDE
(possible if 11th digit = 1 and 15th digit = U, V, or W;
possible if 11th digit = 4 and 15th digit = W)
–
–
✔
G09
External fan DE right, air inlet at DE
(possible if 11th digit = 1 and 15th digit = U, V, or W;
possible if 11th digit = 4 and 15th digit = W)
–
–
✔
G11
External fan DE top, air inlet at DE
(possible if 11th digit = 1 and 15th digit = U, V, or W;
possible if 11th digit = 4 and 15th digit = W)
–
–
✔
G14
With air filter
(only possible when 11th data position is "1" or "4")
Only for SH 132
and SH 160
✔
✔
G50
Nipple for SPM, with M8 adapter
–
✔
✔
G80
Mounting of a POG 10 incremental encoder supplied by customer
(possible if 9th data position is "K")
–
–
✔
H56
Mounting of an incremental encoder POG 10 D 1024 (encoder HTL1024 S/R)
(possible if 9th data position is "K")
–
–
✔
H75
Mounting of a hollow-shaft encoder HOG 22 supplied by customer
(possible if 9th data position is "G")
–
–
✔
K08
Encoder connector or DRIVE-CLiQ mounted opposite
(not possible when 15th data position is "X")
–
✔
✔
K09
Terminal box or power connector NDE right
Only for SH 100
2)
to SH 160
–
–
Terminal box NDE right, cable entry DE, signal connection top
(possible if 15th data position is "A")
–
✔
–
K10
Terminal box or power connector NDE left
Only for SH 100
2)
to SH 160
–
–
Terminal box NDE left, cable entry DE, signal connection top
(possible if 15th data position is "A")
–
✔
–
K16
Second shaft extension (d × l: 95 mm × 170 mm (3.74 in × 6.69 in))
(possible if 9th data position is "A" or "G" and 12th data position is "0" or "3")
–
–
✔
K17
Labyrinth seal DE for Performance version
(possible if 12th data position is "5" and 14th data position is "L"
–
Only for SH 180
–
K18
Radial shaft sealing ring DE
3)
✔
✔
–
K40
Regreasing system, DE and NDE
–
Only for SH 180
and SH 225
Standard
–
Not possible
✔
Option available
1)
Not possible with shaft height 280 and when 14th data position is "E" or "F" (increased radial forces).
2)
Not possible when 12th data position is "2" (type of construction IM B5)
3)
Only appropriate if oil spray or oil vapor is occasionally deposited on the sealing ring.
Radial shaft sealing ring not possible when:
14th data position is "E", "F" or "L".
© Siemens AG 2017