SIEMENS
9/34
Siemens D 21.4 · 2017
SIMOTICS main motors
SIMOTICS M asynchronous and synchronous motors for SINAMICS S120
SIMOTICS M-1PH8 asynchronous motors
> Forced ventilation, IP23 degree of protection
9
■
Selection and ordering data
Rated
speed
Shaft
height
Rated power
Rated torque
Rated
current
Rated
voltage
Rated
frequency
Operating
speed during
field weakening,
max.
1)
Speed,
max.
2)
SIMOTICS M-1PH8
asynchronous motors
Forced ventilation
n
rated
SH
P
rated
M
rated
I
rated
U
rated
f
rated
n
2
n
max
rpm
kW (hp)
Nm (lb
f
-ft)
A
V
Hz
rpm
rpm
Article No.
Line voltage 690 V 3 AC, Basic Line Module
700
280
162 (217)
2210 (1630)
184
605
23.9
1200
3300
1PH8284-
1
■
K
4
■
-
.
.
.
.
210 (282)
2865 (2113)
235
605
23.8
1300
3300
1PH8286-
1
■
K
4
■
-
.
.
.
.
263 (353)
3588 (2646)
295
605
23.9
1400
3300
1PH8288-
1
■
K
4
■
-
.
.
.
.
1000
280
236 (316)
2254 (1662)
265
600
33.9
1900
3300
1PH8284-
1
■
U
4
■
-
.
.
.
.
299 (401)
2855 (2106)
355
570
33.8
2000
3300
1PH8286-
1
■
U
4
■
-
.
.
.
.
367 (492)
3505 (2585)
425
580
33.8
2100
3300
1PH8288-
1
■
U
4
■
-
.
.
.
.
1500
280
307 (412)
1955 (1442)
345
590
50.6
1900
3300
1PH8284-
1
■
W
4
■
-
.
.
.
.
370 (496)
2356 (1738)
410
590
50.6
2000
3300
1PH8286-
1
■
W
4
■
-
.
.
.
.
465 (624)
2961 (2184)
520
590
50.5
2100
3300
1PH8288-
1
■
W
4
■
-
.
.
.
.
Line voltage 690 V 3 AC, Active Line Module
800
280
185 (248)
2208 (1629)
182
690
27.2
1500
3300
1PH8284-
1
■
K
4
■
-
.
.
.
.
240 (322)
2865 (2113)
235
690
27.2
1600
3300
1PH8286-
1
■
K
4
■
-
.
.
.
.
300 (402)
3581 (2641)
290
690
27.3
1600
3300
1PH8288-
1
■
K
4
■
-
.
.
.
.
1150
280
272 (365)
2255 (1663)
270
690
38.9
2200
3300
1PH8284-
1
■
U
4
■
-
.
.
.
.
344 (461)
2860 (2109)
355
655
38.8
2200
3300
1PH8286-
1
■
U
4
■
-
.
.
.
.
422 (566)
3504 (2584)
425
665
38.8
2200
3300
1PH8288-
1
■
U
4
■
-
.
.
.
.
1750
280
359 (481)
1959 (1445)
345
690
58.9
2200
3300
1PH8284-
1
■
W
4
■
-
.
.
.
.
432 (579)
2356 (1738)
410
690
58.9
2200
3300
1PH8286-
1
■
W
4
■
-
.
.
.
.
543 (728)
2964 (2186)
510
690
58.9
2200
3300
1PH8288-
1
■
W
4
■
-
.
.
.
.
For versions, see
Article No. supplements
and options.
For footnotes, see next page.
© Siemens AG 2017