SIEMENS
12/52
Siemens D 21.4 · 2017
MOTION-CONNECT connection systems
Connection overviews
External measuring systems with DRIVE-CLiQ interface
12
■
Integration
Connection overview of SINAMICS S120 for external measuring systems with M12 connection or RJ45 connection
1
1
1)
Max. 3 M12 disconnection points permissible without derating.
7)
Max. 4 M17 disconnection points permissible without derating.
2)
The total length of the DRIVE-CLiQ line must not exceed 30 m (98.4 ft).
3)
Optional DRIVE-CLiQ M12/IP67 cabinet bushing (6FX2003-0DT67).
4)
Optional DRIVE-CLiQ RJ45/IP67 coupler (6SL3066-2DA00-0AB0), max. 3 couplers permissible with derating
(total permissible cable length ≤ 100 m (328 ft) (6FX5...) or ≤ 75 m (246 ft) (6FX8...) - 5 m (16.4 ft) per coupler).
5)
Optional DME20 DRIVE-CLiQ Hub Module RJ45/IP67 (6SL3055-0AA00-6AB0), max. 2 DME20 Hub Modules possible.
8)
Optional mounting flange (6FX2003-7HX00).
9)
Optional DRIVE-CLiQ cable 6FX.002-2DC44-
.....
10)
Total permissible cable length ≤ 100 m (328 ft) (6FX5...) or ≤ 75 m (246 ft) (6FX8...).
6)
Optional DRIVE-CLiQ RJ45/IP67, RJ45/IP20 cabinet bushing (6SL3066-2DA00-0AA0).
G_NC01_EN_01021
Pre-assembled cable
Article No.
External
measuring
system
with
DRIVE-CLiQ
interface with
M12
connection
External
measuring
system
with
DRIVE-CLiQ
interface with
RJ45
connection
Cabinet
bushing
3)
Coupler
4)
Coupler
4)
(98 ft)
(328 ft)
(246 ft)
Hub
DME20
5)
Cabinet
bushing
6)
Hub
DME20
5)
6FX.002-2DC30-
....
≤ 30 m
1)
7) 8)
7) 8)
1)
SINAMICS S120
6FX.002-2DC30-
....
2)
6FX.002-2DC10-
....
6FX.002-2DC00-
....
6FX.002-
2DC20-
....
6FX.002-
2DD48-
....
6FX.002-
2DC48-
....
6FX.002-
2DC46-
....
6FX.002-
2DC42-
....
6FX.002-
2DD44-
....
9)
6FX.002-
2DC44-
....
9)
6FX.002-2DC34-
....
2)
6FX.002-2DC34-
....
2)
6FX.002-2DC36-
....
6FX.002-2DC20-
....
6FX.002-2DC40-
....
10)
6FX.002-2DD40-
....
10)
6FX5002-2DC10-
....
≤ 100 m
6FX8002-2DC10-
....
≤ 75 m
6FX.002-2DC36-
....
© Siemens AG 2017