SIEMENS
12/30
Siemens D 21.4 · 2017
MOTION-CONNECT connection systems
Signal cables for SINAMICS S120
Signal cables for motors with SPEED-CONNECT connector
12
■
Selection and ordering data
Pre-assembled MOTION-CONNECT signal cables for motors with SPEED-CONNECT
connector
Encoder system
Motor
Connec-
tion via
Length,
max.
D
max
Degree of
protection
Connec-
tor
1)
Basic cable
Extension
SIMOTICS
SINAMICS
m (ft)
mm (in)
Article No.
Article No.
Absolute encoder with EnDat 2.1
S-1FK701
SMC20
50 (164)
9.8 (0.39)
IP20/IP67
6FX
■
0
■
2-2EN20-
....
6FX8002-2EN24-
....
Absolute encoder with EnDat 2.1
S-1FK7
2)
/-1FT7/
M-1PH8
3)
SMC20
100 (328)
9.8 (0.39)
IP20/IP67
6FX
■
0
■
2-2EQ31-
....
6FX
■
002-2EQ34-
....
Incremental encoder sin/cos 1 V
pp
2048 S/R
S-1FK701
SMC20
50 (164)
9.2 (0.36)
IP20/IP67
6FX
■
0
■
2-2CN20-
....
6FX8002-2CN24-
....
Incremental encoder sin/cos 1 V
pp
2048 S/R, with C and D tracks
S-1FK7/-1FT7/
M-1PH8
3)
SMC20
100 (328)
9.8 (0.39)
IP20/IP67
6FX
■
0
■
2-2CQ31-
....
6FX
■
002-2CQ34-
....
Incremental encoder sin/cos 1 V
pp
256 and 512 S/R,
without C and D tracks
M-1PH8
3)
SMC20
50 (164)
9.2 (0.36)
IP20/IP67
6FX80
■
2-2CQ80-
....
6FX
■
002-2CQ34-
....
Resolver
S-1FK701
SMC10
130 (426)
9.2 (0.36)
IP20/IP67
6FX
■
0
■
2-2FN20-
....
6FX8002-2FN24-
....
MOTION-CONNECT 500
5
5
MOTION-CONNECT 800PLUS
8
8
Signal cable
Pre-assembled
0
Connector at module end supplied separately
1
Connector at motor end supplied separately
4
Length code
....
....
1)
The specification for the degree of protection refers to the basic cable.
2)
Not for SIMOTICS S-1FK701 motors.
3)
For SIMOTICS M-1PH808/-1PH810/-1PH813/-1PH816 motors.
© Siemens AG 2017