MOTION-CONNECT connection systems
Signal cables for SINAMICS S120
12
■
Overview
MOTION-CONNECT DRIVE-CLiQ signal cable with IP20/IP67 connector
Signal cables are pre-assembled and are sold by the meter for
connecting a variety of components.
The following different types of cable are available:
•
DRIVE-CLiQ signal cables
•
MOTION-CONNECT DRIVE-CLiQ signal cables
•
MOTION-CONNECT pre-assembled signal cables
Type of delivery for pre-assembled signal cables
Pre-assembled signal cables are available in units of 10 cm
(3.94 in).
The cables are supplied on reels up to 30 kg or 100 m (66.2 lb
or 328 ft). Above 30 kg or 100 m (66.2 lb or 328 ft), cable drums
are used instead of reels.
■
Application
DRIVE-CLiQ signal cables without 24 V DC cores
are used to connect components with DRIVE-CLiQ connections
which have a separate or external
24 V DC power supply.
MOTION-CONNECT DRIVE-CLiQ signal cables with
24 V DC cores
are used whenever components with DRIVE-CLiQ connections
must meet high requirements such as mechanical stress and oil
resistance, e.g., where a connection is made outside the cabinet
between Power Modules, Motor Modules, and
SIMOTICS S-1FK7/SIMOTICS M-1PH8 motors with DRIVE-CLiQ
interface.
MOTION-CONNECT pre-assembled signal cables
are used whenever motor encoders on motors without
DRIVE-CLiQ interface need to be connected to Sensor Modules.
■
Design
If pre-assembled signal cables are to be installed in a cable
carrier in such a way that the connector would inhibit assembly,
pre-assembled cables without assembled connector can also
be supplied. In this case, the contacts of the cables are crimped
and the connector enclosure is supplied separately. After install-
ing the cables, the customer assembles the connector enclo-
sure.
The 6FX.002-2
....
-
....
signal cables are available with crimped
contacts and with the connector enclosure supplied separately
(not in the case of DRIVE-CLiQ signal cables and signal cables
with exposed core ends).
Signal cables with separately supplied
module-end
connector:
in this case, the 6th position of the Article No. must be changed
from
0
to
1
:
6FX.0
1
2-2C...-
....
(not for signal cables for connecting via
terminals or 6FX.002-2AH00-
....
, 6FX.002-2CA12-
....
).
Signal cables with separately supplied
motor-end
connector:
in this case, the 6th position of the Article No. must be changed
from
0
to
4
:
6FX.0
4
2-2C...-
....
(not for signal cables for connecting via
terminals or 6FX8002-2BA20-
....
, 6FX8002-2BA21-
....
).
Note:
Once the contacts have latched into the insulator, they can no
longer be removed.