SIEMENS
12/13
Siemens D 21.4 · 2017
MOTION-CONNECT connection systems
Power cables for SINAMICS S120
Power cables for SIMOTICS S-1FT7/S-1FK7/M-1PH8 motors with full-thread connector
12
■
Selection and ordering data
(continued)
For SIMOTICS S-1FK7/-1FT7 motors with
holding brake and with full-thread connector on
SINAMICS S120 Motor Modules in booksize format
Connection
method,
Motor Module
end
No. of cores
×
cross-section
Connec-
tor size,
motor
end
Pre-assembled cable
with
brake cores
Cable sold by the meter
1)
with
brake cores
D
max
Weight
(without
connector)
Smallest
bending radius
2)
6FX5
6FX8
6FX5
6FX8
6FX5
6FX8
mm
2
Article No.
Article No.
mm
(in)
mm
(in)
kg/m
(lb/ft)
kg/m
(lb/ft)
mm
(in)
mm
(in)
Connector
3)
4
×
1.5+2
×
1.5
0.5
6FX
■
0
■
2-5DS27-
....
6FX5008-1BA11-
....
10.8
(0.43)
–
0.22
(0.15)
–
195
(7.68)
–
1
6FX
■
0
■
2-5DS06-
....
6FX
■
008-1BA11-
....
10.8
(0.43)
12.0
(0.47)
0.22
(0.15)
0.23
(0.15)
195
(7.68)
90
(3.54)
1.5
6FX
■
0
■
2-5DS26-
....
4
×
2.5+2
×
1.5
1
6FX
■
0
■
2-5DS16-
....
6FX
■
008-1BA21-
....
12.4
(0.49)
13.8
(0.54)
0.25
(0.17)
0.30
(0.20)
225
(8.86)
105
(4.13)
1.5
6FX
■
0
■
2-5DS36-
....
4
×
4+2
×
1.5
1.5
6FX
■
0
■
2-5DS46-
....
6FX
■
008-1BA31-
....
14.0
(0.55)
15.2
(0.60)
0.35
(0.24)
0.38
(0.26)
255
(10.04)
115
(4.53)
4
×
6+2
×
1.5
1.5
6FX
■
0
■
2-5DS56-
....
6FX
■
008-1BA41-
....
16.1
(0.63)
17.3
(0.68)
0.49
(0.33)
0.50
(0.34)
290
(11.42)
130
(5.12)
4
×
10+2
×
1.5
1.5
6FX
■
0
■
2-5DS66-
....
6FX
■
008-1BA51-
....
21.7
(0.85)
20.1
(0.79)
0.81
(0.54)
0.71
(0.48)
395
(15.55)
150
(5.91)
3
6FX
■
0
■
2-5DS17-
....
Ring cable
lugs
4)
4
×
6+2
×
1.5
1.5
6FX
■
002-5DS54-
....
6FX
■
008-1BA41-
....
16.1
(0.63)
17.3
(0.68)
0.49
(0.33)
0.50
(0.34)
290
(11.42)
130
(5.12)
6FX
■
042-5DS54-
....
4
×
10+2
×
1.5
1.5
6FX
■
002-5DS64-
....
6FX
■
008-1BA51-
....
21.7
(0.85)
20.1
(0.79)
0.81
(0.54)
0.71
(0.48)
395
(15.55)
150
(5.91)
6FX
■
042-5DS64-
....
3
6FX
■
002-5DS14-
....
6FX
■
042-5DS14-
....
4
×
16+2
×
1.5
3
6FX
■
002-5DS23-
....
6FX
■
008-1BA61-
....
25.0
(0.98)
23.8
(0.94)
1.12
(0.75)
1.03
(0.69)
450
(17.72)
180
(7.09)
6FX
■
042-5DS23-
....
Exposed
core ends
5)
4
×
16+2
×
1.5
3
6FX
■
002-5DG23-
....
6FX
■
008-1BA61-
....
25.0
(0.98)
23.8
(0.94)
1.12
(0.75)
1.03
(0.69)
450
(17.72)
180
(7.09)
6FX
■
042-5DG23-
....
4
×
25+2
×
1.5
3
6FX
■
002-5DG33-
....
6FX
■
008-1BA25-
....
29.4
(1.16)
27.6
(1.09)
1.62
(1.09)
1.47
(0.99)
530
(20.87)
280
(11.02)
6FX
■
042-5DG33-
....
4
×
35+2
×
1.5
3
6FX
■
002-5DG43-
....
6FX
■
008-1BA35-
....
32.6
(1.28)
31.9
(1.26)
2.06
(1.38)
1.92
(1.29)
590
(23.23)
320
(12.60)
6FX
■
042-5DG43-
....
4
×
50+2
×
1.5
3
6FX
■
002-5DG53-
....
6FX
■
008-1BA50-
....
38.0
(1.50)
35.0
(1.38)
3.04
(2.04)
2.56
(1.72)
685
(26.97)
350
(13.78)
6FX
■
042-5DG53-
....
MOTION-CONNECT 500
5
5
MOTION-CONNECT 800PLUS
8
8
Power cable
Pre-assembled
0
Connector at module end supplied separately
1
Connector at module end not supplied
2
Connector at motor end supplied separately
4
Length code
....
....
1)
Note type of delivery.
2)
Valid for installation in a cable carrier.
3)
For SINAMICS S120 Motor Modules in booksize format C/D type, 3 A to 30 A.
4)
For SINAMICS S120 Motor Modules in booksize format, 45 A and 60 A.
5)
Length of core ends: 300 mm (11.81 in). 4 M8 cable lugs, 1 M6 cable lug, and 1 spring-type terminal are also included in the scope of supply of the cables.
© Siemens AG 2017