SIEMENS
12/9
Siemens D 21.4 · 2017
MOTION-CONNECT connection systems
Power cables for SINAMICS S120
Power cables for SIMOTICS S-1FT7/S-1FK7/M-1PH8 motors with SPEED-CONNECT connector
12
■
Selection and ordering data
For SIMOTICS S-1KF7/-1FT7 motors without
holding brake/SIMOTICS M-1PH808/-1PH810 motors with SPEED-CONNECT
connector on SINAMICS S120 Motor Modules in booksize format
Connection
method,
Motor Module
end
No. of cores
×
cross-section
Connec-
tor size,
motor
end
Pre-assembled cable
without
brake cores
Cable sold by the meter
1)
without
brake cores
D
max
Weight
(without
connector)
Smallest
bending radius
2)
6FX5
6FX8
6FX5
6FX8
6FX5
6FX8
mm
2
Article No.
Article No.
mm
(in)
mm
(in)
kg/m
(lb/ft)
kg/m
(lb/ft)
mm
(in)
mm
(in)
Connector
3)
4
×
1.5
0.5
6FX
■
0
■
2-5CN27-
....
6FX
■
008-1BB11-
....
8.4
(0.33)
9.5
(0.37)
0.12
(0.08)
0.15
(0.10)
155
(6.10)
75
(2.95)
1
6FX
■
0
■
2-5CN06-
....
1.5
6FX
■
0
■
2-5CN26-
....
4
×
2.5
1
6FX
■
0
■
2-5CN16-
....
6FX
■
008-1BB21-
....
10.0
(0.39)
11.0
(0.43)
0.21
(0.14)
0.20
(0.13)
180
(7.09)
90
(3.54)
1.5
6FX
■
0
■
2-5CN36-
....
4
×
4
1.5
6FX
■
0
■
2-5CN46-
....
6FX
■
008-1BB31-
....
11.4
(0.45)
12.3
(0.48)
0.27
(0.18)
0.27
(0.18)
210
(8.27)
100
(3.94)
4
×
6
1.5
6FX
■
0
■
2-5CN56-
....
6FX
■
008-1BB41-
....
13.6
(0.54)
14.9
(0.59)
0.37
(0.25)
0.41
(0.28)
245
(9.65)
120
(4.72)
4
×
10
1.5
6FX
■
0
■
2-5CN66-
....
6FX
■
008-1BB51-
....
20.0
(0.79)
18.2
(0.72)
0.73
(0.49)
0.62
(0.42)
360
(14.17)
140
(5.51)
Ring cable
lugs
4)
4
×
6
1.5
6FX
■
002-5CN54-
....
6FX
■
008-1BB41-
....
13.6
(0.54)
14.9
(0.59)
0.37
(0.25)
0.41
(0.28)
245
(9.65)
120
(4.72)
6FX
■
042-5CN54-
....
4
×
10
1.5
6FX
■
002-5CN64-
....
6FX
■
008-1BB51-
....
20.0
(0.79)
18.2
(0.72)
0.73
(0.49)
0.62
(0.42)
360
(14.17)
140
(5.51)
6FX
■
042-5CN64-
....
MOTION-CONNECT 500
5
5
MOTION-CONNECT 800PLUS
8
8
Power cable
Pre-assembled
0
Connector at module end supplied separately
1
Connector at module end not supplied
2
Connector at motor end supplied separately
4
Length code
....
....
1)
Note type of delivery.
2)
Valid for installation in a cable carrier.
3)
For SINAMICS S120 Motor Modules in booksize format C/D type, 3 A to 30 A.
4)
For SINAMICS S120 Motor Modules in booksize format, 45 A and 60 A.
© Siemens AG 2017