SIEMENS
10/41
Siemens D 21.4 · 2017
SIMOTICS linear and torque motors
SIMOTICS T torque motors for SINAMICS S120
SIMOTICS T-1FW3 complete torque motors
> Water cooling
10
Motor type
(repeated)
Static torque
Stall
current
Effi-
ciency
3)
Moment of
inertia
Weight,
approx.
Terminal
box
SINAMICS S120 Motor Module
Rated
output current
4)
Internal air cooling
For further components
see SINAMICS S120
drive system
M
0
at
Δ
T
=100 K
I
0
at
Δ
T
=100 K
η
J
m
I
rated
Nm (lb
f
-ft)
A
kgm
2
(lb
f
-in-s
2
)
kg (lb)
Type
A
Article No.
1FW3150-1.H.2-
....
105 (77.4)
7.3
0.89
0.12 (1.06)
87 (192)
gk230
9
6SL3120-1TE21-0AD.
1FW3152-1.H.2-
....
210 (155)
15
0.92
0.16 (1.42)
108 (238)
gk230
18
6SL3120-1TE21-8AD.
1FW3154-1.H.2-
....
315 (232)
21.5
0.93
0.20 (1.77)
129 (284)
gk230
30
6SL3120-1TE23-0AD.
1FW3155-1.H.2-
....
420 (310)
29
0.94
0.24 (2.12)
150 (331)
gk230
30
6SL3120-1TE23-0AD.
1FW3156-1.H.2-
....
525 (387)
35
0.94
0.28 (2.48)
171 (377)
gk230
45
6SL3120-1TE24-5AA.
1FW3201-1.H.2-
....
315 (232)
24
0.92
0.22 (1.95)
127 (280)
gk230
30
6SL3120-1TE23-0AD.
1FW3202-1.H.2-
....
525 (387)
39
0.94
0.36 (3.19)
156 (344)
gk230
45
6SL3120-1TE24-5AA.
1FW3203-1.H.2-
....
790 (583)
62
0.95
0.49 (4.34)
182 (401)
gk420
60
6SL3120-1TE26-0AA.
1FW3204-1.H.2-
....
1050 (774)
77
0.95
0.70 (6.2)
225 (496)
gk420
85
6SL3120-1TE28-5AA.
1FW3206-1.H.2-
....
1575 (1162)
121
0.95
0.97 (8.59)
280 (617)
gk630
132
6SL3120-1TE31-3AA.
1FW3208-1.H.2-
....
2100 (1549)
160
0.94
1.31 (11.6)
350 (772)
gk630
200
6SL3120-1TE32-0AA.
1FW3281-3.J.3-
....
2500 (1844)
200
0.96
3.78 (33.5)
600 (1323)
1XB7700
200
6SL3120-1TE32-0AA.
1FW3283-3.J.3-
....
3500 (2581)
292
0.96
4.64 (41.1)
690 (1521)
1XB7700
310
6SL3320-1TE33-1AA.
1FW3285-3.J.3-
....
5000 (3688)
400
0.96
5.98 (52.9)
860 (1896)
1XB7700
380
6SL3320-1TE33-8AA.
1FW3287-3.J.3-
....
7000 (5163)
534
0.97
7.81 (69.1)
1030 (2271)
1XB7712
618
5)
6SL3320-1TE37-5AA.
Format:
Booksize
Chassis
1
3
Motor Module:
Single Motor Module
1
Version status
1)
Maximum permissible operating speed based on the induced voltage in the motor and the voltage strength of the converter (without protective circuit).
2)
Maximum speed that must not be exceeded. Certain constraints may apply, see article number supplements.
3)
Optimum efficiency in continuous duty.
4)
The rated pulse frequencies must be taken into account. The rated motor data is valid for 4 kHz or 2 kHz.
5)
The rated output current of the Motor Module is lower than the rated motor current at 2 kHz.
© Siemens AG 2017