SIEMENS
10/34
Siemens D 21.4 · 2017
SIMOTICS linear and torque motors
SIMOTICS T torque motors for SINAMICS S120
SIMOTICS T-1FW6 built-in torque motors
> Water cooling
10
■
Selection and ordering data
Maximum
torque
Static torque
1)
3)
Rated torque
2)
3)
Speed at
maximum torque,
max.
2)
Rated speed
2)
SIMOTICS T-1FW6
built-in torque motor
Moment of inertia
Rotor
Weight, approx.
Stator + rotor
M
max
M
0
M
rated
n
max
at
M
max
n
rated
J
m
Nm (lb
f
-ft)
Nm (lb
f
-ft)
Nm (lb
f
-ft)
rpm
rpm
Article No.
10
-2
kgm
2
(10
-3
x lb
f
-in-s
2
)
kg (lb)
Water cooling
4000 (2950)
2220 (1637)
2060 (1519)
57.5
106
1FW6290-0
■
B07-5G
■
2
228 (202)
103.6 (228)
1920 (1416)
110
204
1FW6290-0
■
B07-0L B2
1810 (1335)
144
272
1FW6290-0
■
B07-2PB2
108.8 (240)
6280 (4632)
3490 (2574)
3320 (2449)
39.3
72.9
1FW6290-0
■
B11-7A
■
2
334 (296)
159 (351)
3200 (2360)
68.6
125
1FW6290-0
■
B11-0L B2
3110 (2294)
90.4
165
1FW6290-0
■
B11-2PB2
164.2 (362)
8570 (6321)
4760 (3511)
4600 (3393)
26.6
51.3
1FW6290-0
■
B15-7A
■
2
440 (389)
214.6 (473)
4480 (3304)
48.7
88.5
1FW6290-0
■
B15-0L B2
4390 (3238)
64.9
117
1FW6290-0
■
B15-2PB2
219.8 (485)
10900 (8039)
6030 (4447)
5760 (4248)
36.9
67.9
1FW6290-0
■
B20-0L B2
546 (483)
260.6 (575)
5670 (4182)
49.9
90.3
1FW6290-0
■
B20-2PB2
265.8 (586)
Cable outlet
only
for 1FW6160 to 1FW6290:
Axial
Radially outwards
Tangential (only
for types of connection C and D)
W
V
T
Type of connection:
Permanently connected power and signal cables with exposed core ends
4)
Length: 2 m (6.56 ft)
Permanently connected power and signal cables pre-assembled with connectors
Length: 0.5 m (1.64 ft)
C
D
Type of connection only
for specific motors
(not
selectable)
:
Permanently connected power and signal cables with exposed core ends
4)
Length: 1 m (3.28 ft)
B
For footnotes, see next page.
© Siemens AG 2017