SIEMENS
10/31
Siemens D 21.4 · 2017
SIMOTICS linear and torque motors
SIMOTICS T torque motors for SINAMICS S120
SIMOTICS T-1FW6 built-in torque motors
> Water cooling
10
Motor type
(repeated)
Stall
current
1)
3)
Rated
current
2)
3)
Maximum
current
2)
Calculated
power
SINAMICS S120 Motor Module
5)
Power cable with complete shield
Motor connection via power connector
4)
Required
rated
current
in booksize format
Internal air cooling
For further components
see SINAMICS S120
drive system
Power
con-
nector
Cable
cross-
section
6)
Pre-assembled
basic cable to
drive system
I
0
I
rated
I
max
P
el, max
I
rated
/
I
max
A
A
A
kW (hp)
A
Article No.
Size
mm
2
Article No.
1FW6190-0.B05-1J..
18
17
32
16.4 (22.0)
18/36
6SL312
0
-
■
TE21-8AC.
1
4
×
2.5
6FX8002-5CS16-
....
1FW6190-0.B05-2J..
27
24
48
20.5
(27.5)
30/56
6SL312
0
-
1
TE23-0AC.
1.5
4
×
4
6FX8002-5CS46-
....
1FW6190-0.B05-5G..
55
41
95
32.2 (43.2)
60/113
6SL312
0
-
1
TE26-0AA.
1.5
4
×
16
6FX8002-5CS24-
....
1FW6190-0.B07-1J..
18
17
32
18.4 (24.7)
18/36
6SL312
0
-
■
TE21-8AC.
1
4
×
2.5
6FX8002-5CS16-
....
1FW6190-0.B07-2J..
27
25
48
22.7 (30.4)
30/56
6SL312
0
-
1
TE23-0AC.
1.5
4
×
4
6FX8002-5CS46-
....
1FW6190-0.B07-5G..
55
45
95
34.6 (46.4)
60/113
6SL312
0
-
1
TE26-0AA.
1.5
4
×
16
6FX8002-5CS24-
....
1FW6190-0.B07-8FB.
78
57
136
45 (60.3)
85/141
6SL312
0
-
1
TE28-5AA.
–
–
–
1FW6190-0.B10-1J..
18
18
32
21 (28.2)
18/36
6SL312
0
-
■
TE21-8AC.
1
4
×
2.5
6FX8002-5CS16-
....
1FW6190-0.B10-2J..
27
26
48
25.8 (34.6)
30/56
6SL312
0
-
1
TE23-0AC.
1.5
4
×
4
6FX8002-5CS46-
....
1FW6190-0.B10-5G..
55
48
95
38.1 (51.1)
60/113
6SL312
0
-
1
TE26-0AA.
1.5
4
×
16
6FX8002-5CS24-
....
1FW6190-0.B10-8FB.
78
65
136
48.7 (65.3)
85/141
6SL312
0
-
1
TE28-5AA.
–
–
–
1FW6190-0.B10-2PB.
123
86
214
67.7 (90.8)
132/210
6SL312
0
-
1
TE31-3AA.
–
–
–
1FW6190-0.B15-2J..
27
26
48
30.4 (40.8)
30/56
6SL312
0
-
1
TE23-0AC.
1.5
4
×
4
6FX8002-5CS46-
....
1FW6190-0.B15-5G..
55
51
95
43.6 (58.5)
60/113
6SL312
0
-
1
TE26-0AA.
1.5
4
×
16
6FX8002-5CS24-
....
1FW6190-0.B15-8FB.
78
70
136
54.6 (73.2)
85/141
6SL312
0
-
1
TE28-5AA.
–
–
–
1FW6190-0.B15-2PB.
123
100
214
73.7 (98.8)
132/210
6SL312
0
-
1
TE31-3AA.
–
–
–
1FW6190-0.B15-0WB.
156
118
272
88.5 (119)
200/282
6SL312
0
-
1
TE32-0AA.
–
–
–
1FW6190-0.B20-5G..
55
52
95
48.8 (65.4)
60/113
6SL312
0
-
1
TE26-0AA.
1.5
4
×
16
6FX8002-5CS24-
....
1FW6190-0.B20-8FB.
78
72
136
60.3 (80.9)
85/141
6SL312
0
-
1
TE28-5AA.
–
–
–
1FW6190-0.B20-2PB.
123
107
214
79.5 (107)
132/210
6SL312
0
-
1
TE31-3AA.
–
–
–
1FW6190-0.B20-0WB.
156
129
272
94.6 (127)
200/282
6SL312
0
-
1
TE32-0AA.
–
–
–
Motor Module:
Single Motor Module
Double Motor Module
1
2
Length codes
....
For information on the cables, refer to
MOTION-CONNECT connection systems
Version status
1)
Torque and current at low speeds.
2)
The values refer to a supply voltage of 400 V 3 AC ±10 % (drive system DC link voltage 600 V DC).
3)
In case of water cooling with inlet temperature of 35 °C (95 °F) and maximum rotor flange temperature of 60 °C (140 °F).
4)
For type of connection with exposed core ends, power and signal connectors are not included in the scope of supply of the motor and must be ordered
separately.
5)
Optimized selection for full performance of torque motors.
6)
The current carrying capacity of the power cables complies with EN 60204-1 for installation type C, for continuous duty at an ambient air temperature of
40 °C (104 °F).
© Siemens AG 2017