SIEMENS
10/23
Siemens D 21.4 · 2017
SIMOTICS linear and torque motors
SIMOTICS T torque motors for SINAMICS S120
SIMOTICS T-1FW6 built-in torque motors
> Natural cooling
10
Motor type
(repeated)
Stall
current
1)
Rated
current
2)
Maximum
current
2)
Calculated
power
SINAMICS S120 Motor Module
3)
Power cable with complete shield
Motor connection via power connector
4)
Required
rated
current
in booksize format
Internal air cooling
For further components
see SINAMICS S120
drive system
Power
con-
nector
Cable
cross-
section
5)
Pre-assembled
basic cable to
drive system
I
0
I
rated
I
max
P
el, max
I
rated
/
I
max
A
A
A
kW (hp)
A
Article No.
Size
mm
2
Article No.
1FW6053-0.B03-0F..
2.3
2.04
7.61
4.2 (5.63)
3/9
6SL3120-
■
TE13-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6053-0.B05-0F..
2
1.7
7.64
4.6 (6.17)
3/9
6SL3120-
■
TE13-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6053-0.B07-0K..
3.4
2.68
14.6
8.8 (11.8)
5/15
6SL3120-
■
TE15-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6053-0.B10-0K..
3.1
2.31
14.6
9.2 (12.3)
5/15
6SL3120-
■
TE15-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6053-0.B15-1J..
5.4
3.78
29.1
17.5 (23.5)
18/36
6SL3120-
■
TE21-8AC.
1
4
×
2.5
6FX8002-5CS16-….
1FW6063-0.B03-0F..
2.1
1.86
9.81
6 (8.05)
3/9
6SL3120-
■
TE13-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6063-0.B05-0K..
3.3
2.8
17.7
10.3 (13.8)
9/27
6SL3120-
■
TE21-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6063-0.B07-0K..
3
2.42
17.8
10.9 (14.6)
9/27
6SL3120-
■
TE21-0AD.
1
4
×
2.5
6FX8002-5CS16-….
1FW6063-0.B10-1J..
5
3.71
31.5
19.1 (25.6)
18/36
6SL3120-
■
TE21-8AC.
1
4
×
2.5
6FX8002-5CS16-….
1FW6063-0.B15-1J..
4.3
3.45
31.5
20.4 (27.4)
18/36
6SL3120-
■
TE21-8AC.
1
4
×
2.5
6FX8002-5CS16-….
Motor Module:
Single Motor Module
Double Motor Module
1
2
Length codes
....
For information on the cables, refer to
MOTION-CONNECT connection systems
Version status
1)
Torque and current at low speeds.
2)
The values refer to a supply voltage of 400 V 3 AC ±10 % (drive system DC link voltage 600 V DC).
3)
Optimized selection for full performance of torque motors.
4)
For type of connection with exposed core ends, power and signal connectors are not included in the scope of supply of the motor and must be ordered
separately.
5)
The current carrying capacity of the power cables complies with EN 60204-1 for installation type C, for continuous duty at an ambient air temperature of
40 °C (104 °F).
© Siemens AG 2017